Saved in:
| Main Author: | |
|---|---|
| Format: | Dataset Open Access |
| Language: | en |
| Published: |
PANGAEA
2022
|
| Subjects: | |
| Online Access: | https://doi.org/10.1594/PANGAEA.945430 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1867172178075582464 |
|---|---|
| author | Freudenthal, Tim |
| author_facet | Freudenthal, Tim |
| collection | Datos científicos de ciencias marinas y ambientales |
| contents | Drilling data at site GeoB23231-1 were collected during operation of the sea floor drill rig MARUM-MeBo200 during research expedition SO266 in November 2018 on the southern parto of the summit of Four Way Closure Ridge at the South China Sea. Vertical movements of the drill head are monitored with an electromagnetic encoder type TXN 11551 FD by TWK Supreme Sensoric GmbH. Drilling depth was calculated by summing up the drill head movements with the drill being connected to the drill string. The accuracy of the calculated drilling depth is about 0.1%. Flow rate of the flush water was measured within the pressure line of the flush water pump by using a RN3/32/15SP360 flowmeter by UK Flowtechnik. The accuracy of the measurement is better than 0.2% |
| format | Dataset Open Access |
| id | pangaea_https___doi_org_10_1594_PANGAEA_945430 |
| institution | PANGAEA |
| language | en |
| publishDate | 2022 |
| publisher | PANGAEA |
| record_format | pangaea |
| spellingShingle | Drilling data at MeBo200 drill site GeoB23231-1, South China Sea Freudenthal, Tim DATE/TIME; DEPTH, sediment/rock; Drilling data; Flowmeter RN3/32/15SP360, UK Flowtechnik; Flow rate; GeoB23231-1; MeBo200; SO266_31-1; SO266/1; Sonne_2 Drilling data at site GeoB23231-1 were collected during operation of the sea floor drill rig MARUM-MeBo200 during research expedition SO266 in November 2018 on the southern parto of the summit of Four Way Closure Ridge at the South China Sea. Vertical movements of the drill head are monitored with an electromagnetic encoder type TXN 11551 FD by TWK Supreme Sensoric GmbH. Drilling depth was calculated by summing up the drill head movements with the drill being connected to the drill string. The accuracy of the calculated drilling depth is about 0.1%. Flow rate of the flush water was measured within the pressure line of the flush water pump by using a RN3/32/15SP360 flowmeter by UK Flowtechnik. The accuracy of the measurement is better than 0.2% |
| title | Drilling data at MeBo200 drill site GeoB23231-1, South China Sea |
| topic | DATE/TIME; DEPTH, sediment/rock; Drilling data; Flowmeter RN3/32/15SP360, UK Flowtechnik; Flow rate; GeoB23231-1; MeBo200; SO266_31-1; SO266/1; Sonne_2 |
| url | https://doi.org/10.1594/PANGAEA.945430 |