Зміст:
- <p>This technical report defines a continuous-duty tendon transmission architecture for humanoid hands and a garage-replicable validation protocol for lifetime, creep, fatigue, and thermal drift. Using UHMWPE as an industrial baseline, the work establishes explicit TRL pass/fail criteria: ≥10⁷ actuation cycles, <2 % length drift, zero retensioning, and thermally stable operation. The architecture is mechanically compatible with palm-centralized actuation, fluid-tendon cooling, and passive finger structures and is field-serviceable without distal disassembly. The protocol provides a standardized benchmark for current humanoid systems and a direct evaluation path for future high-performance tendon materials.</p>