GEM-based TPC with CCD Imaging for Directional Dark Matter Detection

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Phan, N. S., Lauer, R. J., Lee, E. R., Loomba, D., Matthews, J. A. J., Miller, E. H.
Natura: Preprint
Pubblicazione: 2015
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866910531819929600
author Phan, N. S.
Lauer, R. J.
Lee, E. R.
Loomba, D.
Matthews, J. A. J.
Miller, E. H.
author_facet Phan, N. S.
Lauer, R. J.
Lee, E. R.
Loomba, D.
Matthews, J. A. J.
Miller, E. H.
contents The world's leading directional dark matter experiments currently all utilize low-pressure gas Time Projection Chamber (TPC) technologies. We discuss some of the challenges for this technology, for which balancing the goal of achieving the best sensitivity with that of cost effective scale-up requires optimization over a large parameter space. Critical for this are the precision measurements of the fundamental properties of both electron and nuclear recoil tracks down to the lowest detectable energies. Such measurements are necessary to provide a benchmark for background discrimination and directional sensitivity that could be used for future optimization studies for directional dark matter experiments. In this paper we describe a small, high resolution, high signal- to-noise GEM-based TPC with a 2D CCD readout designed for this goal. The performance of the detector was characterized using alpha particles, X-rays, gamma-rays, and neutrons, enabling detailed measurements of electron and nuclear recoil tracks. Stable effective gas gains of greater than $1 \times 10^5$ were obtained in 100 Torr of pure CF$_4$ by a cascade of three standard CERN GEMs each with a 140 $μ$m pitch. The high signal-to-noise and sub-millimeter spatial resolution of the GEM amplification and CCD readout, together with low diffusion, allow for excellent background discrimination between electron and nuclear recoils down below $\sim$10 keVee ($\sim$23 keVr fluorine recoil). Even lower thresholds, necessary for the detection of low mass WIMPs for example, might be achieved by lowering the pressure and utilizing full 3D track reconstruction. These and other paths for improvements are discussed, as are possible fundamental limitations imposed by the physics of energy loss.
format Preprint
id arxiv_https___arxiv_org_abs_1510_02170
institution arXiv
publishDate 2015
record_format arxiv
spellingShingle GEM-based TPC with CCD Imaging for Directional Dark Matter Detection
Phan, N. S.
Lauer, R. J.
Lee, E. R.
Loomba, D.
Matthews, J. A. J.
Miller, E. H.
Instrumentation and Detectors
Instrumentation and Methods for Astrophysics
High Energy Physics - Experiment
Nuclear Experiment
The world's leading directional dark matter experiments currently all utilize low-pressure gas Time Projection Chamber (TPC) technologies. We discuss some of the challenges for this technology, for which balancing the goal of achieving the best sensitivity with that of cost effective scale-up requires optimization over a large parameter space. Critical for this are the precision measurements of the fundamental properties of both electron and nuclear recoil tracks down to the lowest detectable energies. Such measurements are necessary to provide a benchmark for background discrimination and directional sensitivity that could be used for future optimization studies for directional dark matter experiments. In this paper we describe a small, high resolution, high signal- to-noise GEM-based TPC with a 2D CCD readout designed for this goal. The performance of the detector was characterized using alpha particles, X-rays, gamma-rays, and neutrons, enabling detailed measurements of electron and nuclear recoil tracks. Stable effective gas gains of greater than $1 \times 10^5$ were obtained in 100 Torr of pure CF$_4$ by a cascade of three standard CERN GEMs each with a 140 $μ$m pitch. The high signal-to-noise and sub-millimeter spatial resolution of the GEM amplification and CCD readout, together with low diffusion, allow for excellent background discrimination between electron and nuclear recoils down below $\sim$10 keVee ($\sim$23 keVr fluorine recoil). Even lower thresholds, necessary for the detection of low mass WIMPs for example, might be achieved by lowering the pressure and utilizing full 3D track reconstruction. These and other paths for improvements are discussed, as are possible fundamental limitations imposed by the physics of energy loss.
title GEM-based TPC with CCD Imaging for Directional Dark Matter Detection
topic Instrumentation and Detectors
Instrumentation and Methods for Astrophysics
High Energy Physics - Experiment
Nuclear Experiment
url https://arxiv.org/abs/1510.02170