Optical probe pressure effects on cutaneous blood flow

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Mizeva, Irina A., Potapova, Elena V., Dremin, Viktor V., Zherebtsov, Evgeny A., Mezentsev, Mikhail A., Shupletsov, Valerii V., Dunaev, Andrey V.
Format: Preprint
Veröffentlicht: 2018
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866913582823768064
author Mizeva, Irina A.
Potapova, Elena V.
Dremin, Viktor V.
Zherebtsov, Evgeny A.
Mezentsev, Mikhail A.
Shupletsov, Valerii V.
Dunaev, Andrey V.
author_facet Mizeva, Irina A.
Potapova, Elena V.
Dremin, Viktor V.
Zherebtsov, Evgeny A.
Mezentsev, Mikhail A.
Shupletsov, Valerii V.
Dunaev, Andrey V.
contents The variation of blood flow characteristics caused by the probe pressure during noninvasive studies is of particular interest within the context of fundamental and applied research. It has been shown previously that the weak local pressure induces vasodilation, whereas the increased pressure is able to stop the blood flow in the compressed area, as well as to significantly change optical signals. The blood flow oscillations measured by laser Doppler flowmetry (LDF) characterize the functional state of the microvascular system and can be used for noninvasive diagnostics of its abnormality. This study was intended to identify the patterns of the relationship between the oscillating components of blood flow registered by the LDF method under different levels of pressure applied to an optical fiber probe. For this purpose we have developed an original optical probe capable of regulating the applied pressure. The developed protocol included six sequential records of the blood perfusion at pressure within the 0 to 200 mmHg range with unloading at the last stage. Using wavelet analyses, we traced the variation of energy of oscillations for these records in five frequency bands associated with different vascular tone regulation mechanisms. Six young volunteers of the same age (three males and three females) were included in this preliminary study and the protocol was repeated five times in each volunteer. Totally 30 LDF records were available for the analyses. As expected, the LDF signal increases at weak pressure (30 mmHg) and decreases at increased pressure. The statistically stable amplification of endothelial associated blood flow oscillations under the 90 mmHg pressure allowed us to put forward a hypothesis that the endothelial activity increases. The possible causes of this phenomenon are discussed.
format Preprint
id arxiv_https___arxiv_org_abs_1811_11443
institution arXiv
publishDate 2018
record_format arxiv
spellingShingle Optical probe pressure effects on cutaneous blood flow
Mizeva, Irina A.
Potapova, Elena V.
Dremin, Viktor V.
Zherebtsov, Evgeny A.
Mezentsev, Mikhail A.
Shupletsov, Valerii V.
Dunaev, Andrey V.
Tissues and Organs
The variation of blood flow characteristics caused by the probe pressure during noninvasive studies is of particular interest within the context of fundamental and applied research. It has been shown previously that the weak local pressure induces vasodilation, whereas the increased pressure is able to stop the blood flow in the compressed area, as well as to significantly change optical signals. The blood flow oscillations measured by laser Doppler flowmetry (LDF) characterize the functional state of the microvascular system and can be used for noninvasive diagnostics of its abnormality. This study was intended to identify the patterns of the relationship between the oscillating components of blood flow registered by the LDF method under different levels of pressure applied to an optical fiber probe. For this purpose we have developed an original optical probe capable of regulating the applied pressure. The developed protocol included six sequential records of the blood perfusion at pressure within the 0 to 200 mmHg range with unloading at the last stage. Using wavelet analyses, we traced the variation of energy of oscillations for these records in five frequency bands associated with different vascular tone regulation mechanisms. Six young volunteers of the same age (three males and three females) were included in this preliminary study and the protocol was repeated five times in each volunteer. Totally 30 LDF records were available for the analyses. As expected, the LDF signal increases at weak pressure (30 mmHg) and decreases at increased pressure. The statistically stable amplification of endothelial associated blood flow oscillations under the 90 mmHg pressure allowed us to put forward a hypothesis that the endothelial activity increases. The possible causes of this phenomenon are discussed.
title Optical probe pressure effects on cutaneous blood flow
topic Tissues and Organs
url https://arxiv.org/abs/1811.11443