Transient Stability Assessment of Power Systems Based on Local Learning Machine and Bacterial Colony Chemotaxis Algorithm

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Gu, Xueping, Li, Yang
Format: Preprint
Published: 2019
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866912161645723648
author Gu, Xueping
Li, Yang
author_facet Gu, Xueping
Li, Yang
contents In order to improve the classification accuracy of transient stability assessment of power systems, a novel method based on local learning machine and an improved bacterial colony chemotaxis (BCC) algorithm is proposed, where local learning machine(LLM) is used to build a TSA model. Considering the possible real-time information provided by PMU, a group of system-level classification features extracted from the power system operation parameters are employed as inputs, and the stability result is used as output of the LLM model. The relation ship between input and output is trained and the ideal model is obtained by applying the improved BCC combined with chaotic search strategy to determine the optimal parameters of LLM automatically. The effectiveness of the proposed method is shown by the simulation results on the New England 10-unit-39-bus power system.
format Preprint
id arxiv_https___arxiv_org_abs_1901_08909
institution arXiv
publishDate 2019
record_format arxiv
spellingShingle Transient Stability Assessment of Power Systems Based on Local Learning Machine and Bacterial Colony Chemotaxis Algorithm
Gu, Xueping
Li, Yang
Signal Processing
Systems and Control
In order to improve the classification accuracy of transient stability assessment of power systems, a novel method based on local learning machine and an improved bacterial colony chemotaxis (BCC) algorithm is proposed, where local learning machine(LLM) is used to build a TSA model. Considering the possible real-time information provided by PMU, a group of system-level classification features extracted from the power system operation parameters are employed as inputs, and the stability result is used as output of the LLM model. The relation ship between input and output is trained and the ideal model is obtained by applying the improved BCC combined with chaotic search strategy to determine the optimal parameters of LLM automatically. The effectiveness of the proposed method is shown by the simulation results on the New England 10-unit-39-bus power system.
title Transient Stability Assessment of Power Systems Based on Local Learning Machine and Bacterial Colony Chemotaxis Algorithm
topic Signal Processing
Systems and Control
url https://arxiv.org/abs/1901.08909