Magneto-Inductive Powering and Uplink of In-Body Microsensors: Feasibility and High-Density Effects

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Dumphart, Gregor, Bitachon, Bertold Ian, Wittneben, Armin
Format: Preprint
Publié: 2019
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866929564657123328
author Dumphart, Gregor
Bitachon, Bertold Ian
Wittneben, Armin
author_facet Dumphart, Gregor
Bitachon, Bertold Ian
Wittneben, Armin
contents This paper studies magnetic induction for wireless powering and the data uplink of microsensors, in particular for future medical in-body applications. We consider an external massive coil array as power source (1 W) and data sink. For sensor devices at 12 cm distance from the array, e.g. beneath the human skin, we compute a minimum coil size of 150 um assuming 50 nW required chip activation power and operation at 750 MHz. A 275 um coil at the sensor allows for 1 Mbit/s uplink rate. Moreover, we study resonant sensor nodes in dense swarms, a key aspect of envisioned biomedical applications. In particular, we investigate the occurring passive relaying effect and cooperative transmit beamforming in the uplink. We show that the frequency- and location-dependent signal fluctuations in such swarms allow for significant performance gains when utilized with adaptive matching, spectrally-aware signaling and node cooperation. The work is based on a general magneto-inductive MIMO system model, which is introduced first.
format Preprint
id arxiv_https___arxiv_org_abs_1902_03989
institution arXiv
publishDate 2019
record_format arxiv
spellingShingle Magneto-Inductive Powering and Uplink of In-Body Microsensors: Feasibility and High-Density Effects
Dumphart, Gregor
Bitachon, Bertold Ian
Wittneben, Armin
Signal Processing
Information Theory
This paper studies magnetic induction for wireless powering and the data uplink of microsensors, in particular for future medical in-body applications. We consider an external massive coil array as power source (1 W) and data sink. For sensor devices at 12 cm distance from the array, e.g. beneath the human skin, we compute a minimum coil size of 150 um assuming 50 nW required chip activation power and operation at 750 MHz. A 275 um coil at the sensor allows for 1 Mbit/s uplink rate. Moreover, we study resonant sensor nodes in dense swarms, a key aspect of envisioned biomedical applications. In particular, we investigate the occurring passive relaying effect and cooperative transmit beamforming in the uplink. We show that the frequency- and location-dependent signal fluctuations in such swarms allow for significant performance gains when utilized with adaptive matching, spectrally-aware signaling and node cooperation. The work is based on a general magneto-inductive MIMO system model, which is introduced first.
title Magneto-Inductive Powering and Uplink of In-Body Microsensors: Feasibility and High-Density Effects
topic Signal Processing
Information Theory
url https://arxiv.org/abs/1902.03989