Practical Accuracy Limits of Radiation-Aware Magneto-Inductive 3D Localization

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Dumphart, Gregor, Schulten, Henry, Bhatia, Bharat, Sulser, Christoph, Wittneben, Armin
Format: Preprint
Published: 2019
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866913566249975808
author Dumphart, Gregor
Schulten, Henry
Bhatia, Bharat
Sulser, Christoph
Wittneben, Armin
author_facet Dumphart, Gregor
Schulten, Henry
Bhatia, Bharat
Sulser, Christoph
Wittneben, Armin
contents The key motivation for the low-frequency magnetic localization approach is that magnetic near-fields are well predictable by a free-space model, which should enable accurate localization. Yet, limited accuracy has been reported for practical systems and it is unclear whether the inaccuracies are caused by field distortion due to nearby conductors, unconsidered radiative propagation, or measurement noise. Hence, we investigate the practical performance limits by means of a calibrated magnetoinductive system which localizes an active single-coil agent with arbitrary orientation, using 4 mW transmit power at 500 kHz. The system uses eight single-coil anchors around a 3m x 3m area in an office room. We base the location estimation on a complex baseband model which comprises both reactive and radiative propagation. The link coefficients, which serve as input data for location estimation, are measured with a multiport network analyzer while the agent is moved with a positioner device. This establishes a reliable ground truth for calibration and evaluation. The system achieves a median position error of 3.2 cm and a 90th percentile of 8.3 cm. After investigating the model error we conjecture that field distortion due to conducting building structures is the main cause of the performance bottleneck. The results are complemented with predictions on the achievable accuracy in more suitable circumstances using the Cramér-Rao lower bound.
format Preprint
id arxiv_https___arxiv_org_abs_1903_11143
institution arXiv
publishDate 2019
record_format arxiv
spellingShingle Practical Accuracy Limits of Radiation-Aware Magneto-Inductive 3D Localization
Dumphart, Gregor
Schulten, Henry
Bhatia, Bharat
Sulser, Christoph
Wittneben, Armin
Signal Processing
Applications
The key motivation for the low-frequency magnetic localization approach is that magnetic near-fields are well predictable by a free-space model, which should enable accurate localization. Yet, limited accuracy has been reported for practical systems and it is unclear whether the inaccuracies are caused by field distortion due to nearby conductors, unconsidered radiative propagation, or measurement noise. Hence, we investigate the practical performance limits by means of a calibrated magnetoinductive system which localizes an active single-coil agent with arbitrary orientation, using 4 mW transmit power at 500 kHz. The system uses eight single-coil anchors around a 3m x 3m area in an office room. We base the location estimation on a complex baseband model which comprises both reactive and radiative propagation. The link coefficients, which serve as input data for location estimation, are measured with a multiport network analyzer while the agent is moved with a positioner device. This establishes a reliable ground truth for calibration and evaluation. The system achieves a median position error of 3.2 cm and a 90th percentile of 8.3 cm. After investigating the model error we conjecture that field distortion due to conducting building structures is the main cause of the performance bottleneck. The results are complemented with predictions on the achievable accuracy in more suitable circumstances using the Cramér-Rao lower bound.
title Practical Accuracy Limits of Radiation-Aware Magneto-Inductive 3D Localization
topic Signal Processing
Applications
url https://arxiv.org/abs/1903.11143