Discrimination of Internal Faults and Other Transients in an Interconnected System with Power Transformers and Phase Angle Regulators

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Bera, Pallav Kumar, Isik, Can, Kumar, Vajendra
Format: Preprint
Publié: 2020
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866912175343271936
author Bera, Pallav Kumar
Isik, Can
Kumar, Vajendra
author_facet Bera, Pallav Kumar
Isik, Can
Kumar, Vajendra
contents This study solves the problem of accurate detection of internal faults and classification of transients in a 5-bus interconnected system for Phase Angle Regulators (PAR) and Power Transformers. The analysis prevents mal-operation of differential relays in case of transients other than faults which include magnetizing inrush, sympathetic inrush, external faults with CT saturation, capacitor switching, non-linear load switching, and ferroresonance. A gradient boosting classifier (GBC) is used to distinguish the internal faults from the transient disturbances based on 1.5 cycles of 3-phase differential currents registered by a change detector. After the detection of an internal fault, GBCs are used to locate the faulty unit (Power Transformer, PAR series, or exciting unit) and identify the type of fault. In case a transient disturbance is detected, another GBC classifies them into the six transient disturbances. Five most relevant frequency and time domain features obtained using Information Gain are used to train and test the classifiers. The proposed algorithm distinguishes the internal faults from the other transients with a balanced accuracy of 99.95%. The faulty transformer unit is located with a balanced accuracy of 99.5% and the different transient disturbances are identified with a balanced accuracy of 99.3%. Moreover, the reliability of the scheme is verified for different rating and connection of the transformers involved, CT saturation, and noise levels in the signals. These GBC classifiers can work together with a conventional differential relay and offer a supervisory control over its operation. PSCAD/EMTDC software is used for simulation of the transients and to develop the two and three-winding transformer models for creating the internal faults including inter-turn and inter-winding faults.
format Preprint
id arxiv_https___arxiv_org_abs_2004_06003
institution arXiv
publishDate 2020
record_format arxiv
spellingShingle Discrimination of Internal Faults and Other Transients in an Interconnected System with Power Transformers and Phase Angle Regulators
Bera, Pallav Kumar
Isik, Can
Kumar, Vajendra
Signal Processing
Systems and Control
This study solves the problem of accurate detection of internal faults and classification of transients in a 5-bus interconnected system for Phase Angle Regulators (PAR) and Power Transformers. The analysis prevents mal-operation of differential relays in case of transients other than faults which include magnetizing inrush, sympathetic inrush, external faults with CT saturation, capacitor switching, non-linear load switching, and ferroresonance. A gradient boosting classifier (GBC) is used to distinguish the internal faults from the transient disturbances based on 1.5 cycles of 3-phase differential currents registered by a change detector. After the detection of an internal fault, GBCs are used to locate the faulty unit (Power Transformer, PAR series, or exciting unit) and identify the type of fault. In case a transient disturbance is detected, another GBC classifies them into the six transient disturbances. Five most relevant frequency and time domain features obtained using Information Gain are used to train and test the classifiers. The proposed algorithm distinguishes the internal faults from the other transients with a balanced accuracy of 99.95%. The faulty transformer unit is located with a balanced accuracy of 99.5% and the different transient disturbances are identified with a balanced accuracy of 99.3%. Moreover, the reliability of the scheme is verified for different rating and connection of the transformers involved, CT saturation, and noise levels in the signals. These GBC classifiers can work together with a conventional differential relay and offer a supervisory control over its operation. PSCAD/EMTDC software is used for simulation of the transients and to develop the two and three-winding transformer models for creating the internal faults including inter-turn and inter-winding faults.
title Discrimination of Internal Faults and Other Transients in an Interconnected System with Power Transformers and Phase Angle Regulators
topic Signal Processing
Systems and Control
url https://arxiv.org/abs/2004.06003