Accelerometric Method for Cuffless Continuous Blood Pressure Measurement

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Das, Mousumi, Choudhary, Tilendra, Sharma, L. N., Bhuyan, M. K.
Natura: Preprint
Pubblicazione: 2020
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866910434058043392
author Das, Mousumi
Choudhary, Tilendra
Sharma, L. N.
Bhuyan, M. K.
author_facet Das, Mousumi
Choudhary, Tilendra
Sharma, L. N.
Bhuyan, M. K.
contents Pulse transit time (PTT) has been widely used for cuffless blood pressure (BP) measurement. But, it requires more than one cardiovascular signals involving more than one sensing device. In this paper, we propose a method for continuous cuffless blood pressure measurement with the help of left ventricular ejection time (LVET). The LVET is estimated using a signal obtained through a micro-electromechanical system (MEMS)-based accelerometric sensor. The sensor acquires a seismocardiogram (SCG) signal at the chest surface, and the LVET information is extracted. Both systolic blood pressure (SBP) and diastolic blood pressure (DBP) are estimated by calibrating the system with the original arterial blood pressure values of the subjects. The proposed method is evaluated using different quantitative measures on the signals collected from ten subjects under the supine position. The performance of the proposed method is also compared with two earlier approaches, where PTT intervals are estimated from electrocardiogram (ECG)-photoplethysmogram (PPG) and SCG-PPG, respectively. The performance results clearly show that the proposed method is comparable with the state-of-the-art methods. Also, the computed blood pressure is compared with the original one, measured through a CNAP system. It gives the mean errors of the estimated systolic BP and diastolic BP within the range of -0.19 +/- 3.3 mmHg and -1.29 +/- 2.6 mmHg, respectively. The mean absolute errors for systolic BP and diastolic BP are 3.2 mmHg and 2.6 mmHg, respectively. The accuracy of BPs estimated from the proposed method satisfies the requirements of the IEEE standard of 5 +/- 8 mmHg deviation, and thus, it may be used for ubiquitous long term blood pressure monitoring.
format Preprint
id arxiv_https___arxiv_org_abs_2008_07899
institution arXiv
publishDate 2020
record_format arxiv
spellingShingle Accelerometric Method for Cuffless Continuous Blood Pressure Measurement
Das, Mousumi
Choudhary, Tilendra
Sharma, L. N.
Bhuyan, M. K.
Signal Processing
Pulse transit time (PTT) has been widely used for cuffless blood pressure (BP) measurement. But, it requires more than one cardiovascular signals involving more than one sensing device. In this paper, we propose a method for continuous cuffless blood pressure measurement with the help of left ventricular ejection time (LVET). The LVET is estimated using a signal obtained through a micro-electromechanical system (MEMS)-based accelerometric sensor. The sensor acquires a seismocardiogram (SCG) signal at the chest surface, and the LVET information is extracted. Both systolic blood pressure (SBP) and diastolic blood pressure (DBP) are estimated by calibrating the system with the original arterial blood pressure values of the subjects. The proposed method is evaluated using different quantitative measures on the signals collected from ten subjects under the supine position. The performance of the proposed method is also compared with two earlier approaches, where PTT intervals are estimated from electrocardiogram (ECG)-photoplethysmogram (PPG) and SCG-PPG, respectively. The performance results clearly show that the proposed method is comparable with the state-of-the-art methods. Also, the computed blood pressure is compared with the original one, measured through a CNAP system. It gives the mean errors of the estimated systolic BP and diastolic BP within the range of -0.19 +/- 3.3 mmHg and -1.29 +/- 2.6 mmHg, respectively. The mean absolute errors for systolic BP and diastolic BP are 3.2 mmHg and 2.6 mmHg, respectively. The accuracy of BPs estimated from the proposed method satisfies the requirements of the IEEE standard of 5 +/- 8 mmHg deviation, and thus, it may be used for ubiquitous long term blood pressure monitoring.
title Accelerometric Method for Cuffless Continuous Blood Pressure Measurement
topic Signal Processing
url https://arxiv.org/abs/2008.07899