Saved in:
Bibliographic Details
Main Authors: Jia, Feng, Littin, Sebastian, Amrein, Philipp, Kroboth, Stefan, Yu, Huijun, Magill, Arthur W., Kuder, Tristan, Bickelhaupt, Sebastian, Laun, Frederik, Ladd, Mark E., Zaitsev, Maxim
Format: Preprint
Published: 2020
Subjects:
Online Access:https://arxiv.org/abs/2012.12813
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866917376053739520
author Jia, Feng
Littin, Sebastian
Amrein, Philipp
Kroboth, Stefan
Yu, Huijun
Magill, Arthur W.
Kuder, Tristan
Bickelhaupt, Sebastian
Laun, Frederik
Ladd, Mark E.
Zaitsev, Maxim
author_facet Jia, Feng
Littin, Sebastian
Amrein, Philipp
Kroboth, Stefan
Yu, Huijun
Magill, Arthur W.
Kuder, Tristan
Bickelhaupt, Sebastian
Laun, Frederik
Ladd, Mark E.
Zaitsev, Maxim
contents Diffusion-weighted imaging (DWI) in the female breast is a magnetic resonance imaging (MRI) technique, which may potentially replace or effectively complement both x-ray mammography and contrast-enhanced MR mammography. To further improve specificity of DWI in the breast, stronger and faster diffusion weighting is advantageous. With the target application in mind, the gradient coil is designed on an irregularly shaped semi-open current-carrying surface. Due to the coil former closely fitting the non-spherical target region, non-linear encoding fields become particularly advantageous for achieving locally exceptionally high gradient strengths. As the breast tissue has a predominantly isotropic cellular microstructure, the direction of the diffusion-weighting gradient may be allowed to vary within the target volume. However, due to the quadratic dependency of the b-factor on the gradient strength, variation of the gradient magnitude needs to be carefully controlled. To achieve the above design goals the corresponding multi-objective optimization problem is reformulated as a constrained optimization, allowing for flexible and precise control of the coil properties. A novel constraint is proposed limiting the gradient magnitude variation within every slice while allowing for variations both the direction of the gradient within the slice and the magnitude across the slices. The above innovations enable the design of a unilateral coil for diffusion weighting in the female breast with the local gradient strengths exceeding 1~T/m with highly homogeneous diffusion weighting for imaging in the coronal slice orientation.
format Preprint
id arxiv_https___arxiv_org_abs_2012_12813
institution arXiv
publishDate 2020
record_format arxiv
spellingShingle Design of a non-linear human breast diffusion coil
Jia, Feng
Littin, Sebastian
Amrein, Philipp
Kroboth, Stefan
Yu, Huijun
Magill, Arthur W.
Kuder, Tristan
Bickelhaupt, Sebastian
Laun, Frederik
Ladd, Mark E.
Zaitsev, Maxim
Medical Physics
Diffusion-weighted imaging (DWI) in the female breast is a magnetic resonance imaging (MRI) technique, which may potentially replace or effectively complement both x-ray mammography and contrast-enhanced MR mammography. To further improve specificity of DWI in the breast, stronger and faster diffusion weighting is advantageous. With the target application in mind, the gradient coil is designed on an irregularly shaped semi-open current-carrying surface. Due to the coil former closely fitting the non-spherical target region, non-linear encoding fields become particularly advantageous for achieving locally exceptionally high gradient strengths. As the breast tissue has a predominantly isotropic cellular microstructure, the direction of the diffusion-weighting gradient may be allowed to vary within the target volume. However, due to the quadratic dependency of the b-factor on the gradient strength, variation of the gradient magnitude needs to be carefully controlled. To achieve the above design goals the corresponding multi-objective optimization problem is reformulated as a constrained optimization, allowing for flexible and precise control of the coil properties. A novel constraint is proposed limiting the gradient magnitude variation within every slice while allowing for variations both the direction of the gradient within the slice and the magnitude across the slices. The above innovations enable the design of a unilateral coil for diffusion weighting in the female breast with the local gradient strengths exceeding 1~T/m with highly homogeneous diffusion weighting for imaging in the coronal slice orientation.
title Design of a non-linear human breast diffusion coil
topic Medical Physics
url https://arxiv.org/abs/2012.12813