Time to revisit the endpoint dilution assay and to replace TCID$_{50}$ and PFU as measures of a virus sample's infection concentration

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Cresta, Daniel, Warren, Donald C., Quirouette, Christian, Smith, Amanda P., Lane, Lindey C., Smith, Amber M., Beauchemin, Catherine A. A.
Format: Preprint
Published: 2021
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866910391040212992
author Cresta, Daniel
Warren, Donald C.
Quirouette, Christian
Smith, Amanda P.
Lane, Lindey C.
Smith, Amber M.
Beauchemin, Catherine A. A.
author_facet Cresta, Daniel
Warren, Donald C.
Quirouette, Christian
Smith, Amanda P.
Lane, Lindey C.
Smith, Amber M.
Beauchemin, Catherine A. A.
contents The infectivity of a virus sample is measured by the infections it causes, via a plaque or focus forming assay (PFU or FFU) or an endpoint dilution (ED) assay (TCID$_{50}$, CCID$_{50}$, EID$_{50}$, etc., hereafter collectively ID$_{50}$). The counting of plaques or foci at a given dilution intuitively and directly provides the concentration of infectious doses in the undiluted sample. However, it has many technical and experimental limitations. For example, it relies on one's judgement in distinguishing between two merged plaques and a larger one, or between small plaques and staining artifacts. In this regard, ED assays are more robust because one need only determine whether infection occurred. The output of the ED assay, the 50% infectious dose (ID$_{50}$), is calculated using either the Spearman-Karber (SK, 1908,1931) or Reed-Muench (RM, 1938) mathematical approximations. However, these are often miscalculated and their ID$_{50}$ approximation is biased. We propose that the PFU and FFU assays be abandoned, and that the measured output of the ED assay, the ID$_{50}$, be replaced by a more useful measure we coined Specific INfections (SIN). We introduce a free, open-source web-application, midSIN, that computes the SIN concentration in a virus sample from a standard ED assay, requiring no changes to current experimental protocols. We demonstrate that the SIN/mL of a sample reliably corresponds to the number of infections the sample will cause per unit volume, and directly relates to the multiplicity of infection. midSIN estimates are shown to be more accurate and robust than those using the RM and SK approximations. The impact of ED plate design choices (dilution factor, replicates per dilution) on measurement accuracy is also explored. The simplicity of SIN as a measure and the greater accuracy of midSIN make them an easy, superior replacement for the PFU, FFU, and ID$_{50}$ measures.
format Preprint
id arxiv_https___arxiv_org_abs_2101_11526
institution arXiv
publishDate 2021
record_format arxiv
spellingShingle Time to revisit the endpoint dilution assay and to replace TCID$_{50}$ and PFU as measures of a virus sample's infection concentration
Cresta, Daniel
Warren, Donald C.
Quirouette, Christian
Smith, Amanda P.
Lane, Lindey C.
Smith, Amber M.
Beauchemin, Catherine A. A.
Quantitative Methods
62P10, 62-04
J.3; G.1.10; G.3
The infectivity of a virus sample is measured by the infections it causes, via a plaque or focus forming assay (PFU or FFU) or an endpoint dilution (ED) assay (TCID$_{50}$, CCID$_{50}$, EID$_{50}$, etc., hereafter collectively ID$_{50}$). The counting of plaques or foci at a given dilution intuitively and directly provides the concentration of infectious doses in the undiluted sample. However, it has many technical and experimental limitations. For example, it relies on one's judgement in distinguishing between two merged plaques and a larger one, or between small plaques and staining artifacts. In this regard, ED assays are more robust because one need only determine whether infection occurred. The output of the ED assay, the 50% infectious dose (ID$_{50}$), is calculated using either the Spearman-Karber (SK, 1908,1931) or Reed-Muench (RM, 1938) mathematical approximations. However, these are often miscalculated and their ID$_{50}$ approximation is biased. We propose that the PFU and FFU assays be abandoned, and that the measured output of the ED assay, the ID$_{50}$, be replaced by a more useful measure we coined Specific INfections (SIN). We introduce a free, open-source web-application, midSIN, that computes the SIN concentration in a virus sample from a standard ED assay, requiring no changes to current experimental protocols. We demonstrate that the SIN/mL of a sample reliably corresponds to the number of infections the sample will cause per unit volume, and directly relates to the multiplicity of infection. midSIN estimates are shown to be more accurate and robust than those using the RM and SK approximations. The impact of ED plate design choices (dilution factor, replicates per dilution) on measurement accuracy is also explored. The simplicity of SIN as a measure and the greater accuracy of midSIN make them an easy, superior replacement for the PFU, FFU, and ID$_{50}$ measures.
title Time to revisit the endpoint dilution assay and to replace TCID$_{50}$ and PFU as measures of a virus sample's infection concentration
topic Quantitative Methods
62P10, 62-04
J.3; G.1.10; G.3
url https://arxiv.org/abs/2101.11526