Development of the Lymphatic System in the 4D XCAT Phantom

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Fedrigo, Roberto, Segars, William P., Martineau, Patrick, Gowdy, Claire, Bloise, Ingrid, Uribe, Carlos F., Rahmim, Arman
Format: Preprint
Publié: 2021
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866913653810266112
author Fedrigo, Roberto
Segars, William P.
Martineau, Patrick
Gowdy, Claire
Bloise, Ingrid
Uribe, Carlos F.
Rahmim, Arman
author_facet Fedrigo, Roberto
Segars, William P.
Martineau, Patrick
Gowdy, Claire
Bloise, Ingrid
Uribe, Carlos F.
Rahmim, Arman
contents Purpose: The XCAT phantom allows for highly sophisticated multimodality imaging research. It includes a complete set of organs, muscle, bone, soft tissue, while also accounting for age, sex, and body mass index (BMI), which allows phantom studies to be performed at a population scale. At the same time, the XCAT phantom does not currently include the lymphatic system, critical for evaluating bulky nodal malignancies in lymphoma. We aimed to incorporate a full lymphatic system into the XCAT phantom and to generate realistic simulated images via guidance from lymphoma patient studies. Methods: A template lymphatic system was extended based on known anatomy was used to define 276 lymph nodes and corresponding vessels using non-uniform rational basis spline (NURBS) surfaces. Lymph node properties were modified using the Rhinoceros 3D viewing software. The XCAT general parameter script was used to input organ concentrations and generate binary files with uptake and attenuation information. Results: Lymph nodes can be scaled, stretched, and translated within the intuitive Rhinoceros interface, to allow for realistic simulation of different lymph node pathologies. Bulky, heterogeneous PMBCL tumours were generated in the mediastinum using expanded lymph nodes. Our results suggest that optimized thresholding provides better accuracy for determining total metabolic tumour volume (TMTV) of PMBCL tumours, while the gradient method was most accurate for total lesion glycolysis (TLG). Conclusions: An upgraded XCAT phantom with a fully simulated lymphatic system was created. Distributed to the research community, the XCAT phantom with the new lymphatic system has the potential of enabling studies to optimize image quality and quantitation, towards improved assessment of lymphoma including predictive modeling (e.g. improved TMTV and radiomics research).
format Preprint
id arxiv_https___arxiv_org_abs_2107_11429
institution arXiv
publishDate 2021
record_format arxiv
spellingShingle Development of the Lymphatic System in the 4D XCAT Phantom
Fedrigo, Roberto
Segars, William P.
Martineau, Patrick
Gowdy, Claire
Bloise, Ingrid
Uribe, Carlos F.
Rahmim, Arman
Medical Physics
Purpose: The XCAT phantom allows for highly sophisticated multimodality imaging research. It includes a complete set of organs, muscle, bone, soft tissue, while also accounting for age, sex, and body mass index (BMI), which allows phantom studies to be performed at a population scale. At the same time, the XCAT phantom does not currently include the lymphatic system, critical for evaluating bulky nodal malignancies in lymphoma. We aimed to incorporate a full lymphatic system into the XCAT phantom and to generate realistic simulated images via guidance from lymphoma patient studies. Methods: A template lymphatic system was extended based on known anatomy was used to define 276 lymph nodes and corresponding vessels using non-uniform rational basis spline (NURBS) surfaces. Lymph node properties were modified using the Rhinoceros 3D viewing software. The XCAT general parameter script was used to input organ concentrations and generate binary files with uptake and attenuation information. Results: Lymph nodes can be scaled, stretched, and translated within the intuitive Rhinoceros interface, to allow for realistic simulation of different lymph node pathologies. Bulky, heterogeneous PMBCL tumours were generated in the mediastinum using expanded lymph nodes. Our results suggest that optimized thresholding provides better accuracy for determining total metabolic tumour volume (TMTV) of PMBCL tumours, while the gradient method was most accurate for total lesion glycolysis (TLG). Conclusions: An upgraded XCAT phantom with a fully simulated lymphatic system was created. Distributed to the research community, the XCAT phantom with the new lymphatic system has the potential of enabling studies to optimize image quality and quantitation, towards improved assessment of lymphoma including predictive modeling (e.g. improved TMTV and radiomics research).
title Development of the Lymphatic System in the 4D XCAT Phantom
topic Medical Physics
url https://arxiv.org/abs/2107.11429