Operating Principles of Peristaltic Pumping through a Dense Array of Valves

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Winn, Aaron, Katifori, Eleni
Formato: Preprint
Publicado: 2021
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866910704492085248
author Winn, Aaron
Katifori, Eleni
author_facet Winn, Aaron
Katifori, Eleni
contents Immersed nonlinear elements are prevalent in biological systems that require a preferential flow direction, such as the venous and the lymphatic system. We investigate here a certain class of models where the fluid is driven by peristaltic pumping and the nonlinear elements are ideal valves that completely suppress backflow. This highly nonlinear system produces discontinuous solutions that are difficult to study. We show that as the density of valves increases, the pressure and flow are well-approximated by a continuum of valves which can be analytically treated, and we demonstrate through numeric simulation that the approximation works well even for intermediate valve densities. We find that the induced flow is linear in the peristaltic amplitude for small peristaltic forces and, in the case of sinusoidal peristalsis, is independent of pumping direction. Despite the continuum approximation used, the physical valve density is accounted for by modifying the resistance of the fluid appropriately. The suppression of backflow causes a net benefit in adding valves when the valve density is low, but once the density is high enough, valves predominately suppress forward flow, suggesting there is an optimum number of valves per wavelength. The continuum model for peristaltic pumping through an array of valves presented in this work can eventually provide insights about the design and operating principles of complex flow networks with a broad class of nonlinear elements.
format Preprint
id arxiv_https___arxiv_org_abs_2111_11413
institution arXiv
publishDate 2021
record_format arxiv
spellingShingle Operating Principles of Peristaltic Pumping through a Dense Array of Valves
Winn, Aaron
Katifori, Eleni
Fluid Dynamics
Biological Physics
Tissues and Organs
Immersed nonlinear elements are prevalent in biological systems that require a preferential flow direction, such as the venous and the lymphatic system. We investigate here a certain class of models where the fluid is driven by peristaltic pumping and the nonlinear elements are ideal valves that completely suppress backflow. This highly nonlinear system produces discontinuous solutions that are difficult to study. We show that as the density of valves increases, the pressure and flow are well-approximated by a continuum of valves which can be analytically treated, and we demonstrate through numeric simulation that the approximation works well even for intermediate valve densities. We find that the induced flow is linear in the peristaltic amplitude for small peristaltic forces and, in the case of sinusoidal peristalsis, is independent of pumping direction. Despite the continuum approximation used, the physical valve density is accounted for by modifying the resistance of the fluid appropriately. The suppression of backflow causes a net benefit in adding valves when the valve density is low, but once the density is high enough, valves predominately suppress forward flow, suggesting there is an optimum number of valves per wavelength. The continuum model for peristaltic pumping through an array of valves presented in this work can eventually provide insights about the design and operating principles of complex flow networks with a broad class of nonlinear elements.
title Operating Principles of Peristaltic Pumping through a Dense Array of Valves
topic Fluid Dynamics
Biological Physics
Tissues and Organs
url https://arxiv.org/abs/2111.11413