Salvato in:
Dettagli Bibliografici
Autori principali: Tiseo, Carlo, Rouxel, Quentin, Asenov, Martin, Babarahmati, Keyhan Kouhkiloui, Ramamoorthy, Subramanian, Li, Zhibin, Mistry, Michael
Natura: Preprint
Pubblicazione: 2022
Soggetti:
Accesso online:https://arxiv.org/abs/2206.09906
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866909406639161344
author Tiseo, Carlo
Rouxel, Quentin
Asenov, Martin
Babarahmati, Keyhan Kouhkiloui
Ramamoorthy, Subramanian
Li, Zhibin
Mistry, Michael
author_facet Tiseo, Carlo
Rouxel, Quentin
Asenov, Martin
Babarahmati, Keyhan Kouhkiloui
Ramamoorthy, Subramanian
Li, Zhibin
Mistry, Michael
contents Medical robotics can help improve and extend the reach of healthcare services. A major challenge for medical robots is the complex physical interaction between the robot and the patients which is required to be safe. This work presents the preliminary evaluation of a recently introduced control architecture based on the Fractal Impedance Control (FIC) in medical applications. The deployed FIC architecture is robust to delay between the master and the replica robots. It can switch online between an admittance and impedance behaviour, and it is robust to interaction with unstructured environments. Our experiments analyse three scenarios: teleoperated surgery, rehabilitation, and remote ultrasound scan. The experiments did not require any adjustment of the robot tuning, which is essential in medical applications where the operators do not have an engineering background required to tune the controller. Our results show that is possible to teleoperate the robot to cut using a scalpel, do an ultrasound scan, and perform remote occupational therapy. However, our experiments also highlighted the need for a better robots embodiment to precisely control the system in 3D dynamic tasks.
format Preprint
id arxiv_https___arxiv_org_abs_2206_09906
institution arXiv
publishDate 2022
record_format arxiv
spellingShingle Achieving Dexterous Bidirectional Interaction in Uncertain Conditions for Medical Robotics
Tiseo, Carlo
Rouxel, Quentin
Asenov, Martin
Babarahmati, Keyhan Kouhkiloui
Ramamoorthy, Subramanian
Li, Zhibin
Mistry, Michael
Robotics
Medical robotics can help improve and extend the reach of healthcare services. A major challenge for medical robots is the complex physical interaction between the robot and the patients which is required to be safe. This work presents the preliminary evaluation of a recently introduced control architecture based on the Fractal Impedance Control (FIC) in medical applications. The deployed FIC architecture is robust to delay between the master and the replica robots. It can switch online between an admittance and impedance behaviour, and it is robust to interaction with unstructured environments. Our experiments analyse three scenarios: teleoperated surgery, rehabilitation, and remote ultrasound scan. The experiments did not require any adjustment of the robot tuning, which is essential in medical applications where the operators do not have an engineering background required to tune the controller. Our results show that is possible to teleoperate the robot to cut using a scalpel, do an ultrasound scan, and perform remote occupational therapy. However, our experiments also highlighted the need for a better robots embodiment to precisely control the system in 3D dynamic tasks.
title Achieving Dexterous Bidirectional Interaction in Uncertain Conditions for Medical Robotics
topic Robotics
url https://arxiv.org/abs/2206.09906