RRWaveNet: A Compact End-to-End Multi-Scale Residual CNN for Robust PPG Respiratory Rate Estimation

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Osathitporn, Pongpanut, Sawadwuthikul, Guntitat, Thuwajit, Punnawish, Ueafuea, Kawisara, Mateepithaktham, Thee, Kunaseth, Narin, Choksatchawathi, Tanut, Punyabukkana, Proadpran, Mignot, Emmanuel, Wilaiprasitporn, Theerawit
Formato: Preprint
Publicado: 2022
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866917807175761920
author Osathitporn, Pongpanut
Sawadwuthikul, Guntitat
Thuwajit, Punnawish
Ueafuea, Kawisara
Mateepithaktham, Thee
Kunaseth, Narin
Choksatchawathi, Tanut
Punyabukkana, Proadpran
Mignot, Emmanuel
Wilaiprasitporn, Theerawit
author_facet Osathitporn, Pongpanut
Sawadwuthikul, Guntitat
Thuwajit, Punnawish
Ueafuea, Kawisara
Mateepithaktham, Thee
Kunaseth, Narin
Choksatchawathi, Tanut
Punyabukkana, Proadpran
Mignot, Emmanuel
Wilaiprasitporn, Theerawit
contents Respiratory rate (RR) is an important biomarker as RR changes can reflect severe medical events such as heart disease, lung disease, and sleep disorders. Unfortunately, standard manual RR counting is prone to human error and cannot be performed continuously. This study proposes a method for continuously estimating RR, RRWaveNet. The method is a compact end-to-end deep learning model which does not require feature engineering and can use low-cost raw photoplethysmography (PPG) as input signal. RRWaveNet was tested subject-independently and compared to baseline in four datasets (BIDMC, CapnoBase, WESAD, and SensAI) and using three window sizes (16, 32, and 64 seconds). RRWaveNet outperformed current state-of-the-art methods with mean absolute errors at optimal window size of 1.66 \pm 1.01, 1.59 \pm 1.08, 1.92 \pm 0.96 and 1.23 \pm 0.61 breaths per minute for each dataset. In remote monitoring settings, such as in the WESAD and SensAI datasets, we apply transfer learning to improve the performance using two other ICU datasets as pretraining datasets, reducing the MAE by up to 21$\%$. This shows that this model allows accurate and practical estimation of RR on affordable and wearable devices. Our study also shows feasibility of remote RR monitoring in the context of telemedicine and at home.
format Preprint
id arxiv_https___arxiv_org_abs_2208_08672
institution arXiv
publishDate 2022
record_format arxiv
spellingShingle RRWaveNet: A Compact End-to-End Multi-Scale Residual CNN for Robust PPG Respiratory Rate Estimation
Osathitporn, Pongpanut
Sawadwuthikul, Guntitat
Thuwajit, Punnawish
Ueafuea, Kawisara
Mateepithaktham, Thee
Kunaseth, Narin
Choksatchawathi, Tanut
Punyabukkana, Proadpran
Mignot, Emmanuel
Wilaiprasitporn, Theerawit
Signal Processing
Artificial Intelligence
Computer Vision and Pattern Recognition
Machine Learning
Respiratory rate (RR) is an important biomarker as RR changes can reflect severe medical events such as heart disease, lung disease, and sleep disorders. Unfortunately, standard manual RR counting is prone to human error and cannot be performed continuously. This study proposes a method for continuously estimating RR, RRWaveNet. The method is a compact end-to-end deep learning model which does not require feature engineering and can use low-cost raw photoplethysmography (PPG) as input signal. RRWaveNet was tested subject-independently and compared to baseline in four datasets (BIDMC, CapnoBase, WESAD, and SensAI) and using three window sizes (16, 32, and 64 seconds). RRWaveNet outperformed current state-of-the-art methods with mean absolute errors at optimal window size of 1.66 \pm 1.01, 1.59 \pm 1.08, 1.92 \pm 0.96 and 1.23 \pm 0.61 breaths per minute for each dataset. In remote monitoring settings, such as in the WESAD and SensAI datasets, we apply transfer learning to improve the performance using two other ICU datasets as pretraining datasets, reducing the MAE by up to 21$\%$. This shows that this model allows accurate and practical estimation of RR on affordable and wearable devices. Our study also shows feasibility of remote RR monitoring in the context of telemedicine and at home.
title RRWaveNet: A Compact End-to-End Multi-Scale Residual CNN for Robust PPG Respiratory Rate Estimation
topic Signal Processing
Artificial Intelligence
Computer Vision and Pattern Recognition
Machine Learning
url https://arxiv.org/abs/2208.08672