Cluster time measurement with CEPC calorimeter

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Che, Yuzhi, Boudry, Vincent, Videau, Henri, He, Muchen, Ruan, Manqi
Format: Preprint
Publié: 2022
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866917769991159808
author Che, Yuzhi
Boudry, Vincent
Videau, Henri
He, Muchen
Ruan, Manqi
author_facet Che, Yuzhi
Boudry, Vincent
Videau, Henri
He, Muchen
Ruan, Manqi
contents We have developed an algorithm dedicated to timing reconstruction in highly granular calorimeters(HGC). The performance of this algorithm is evaluated on an electromagnetic calorimeter (ECAL) with geometries comparable to the electromagnetic compartment (CE-E) of the CMS endcap calorimeter upgrade at HL-LHC and conceptual Particle Flow oriented ECAL's for future Higgs factories. The time response of individual channel is parameterized according to the CMS experimental result. The particle Time-of-Flight (ToF) can be measured with a resolution of $5\sim20 \;\rm{ps}$ for electromagnetic (EM) showers and $80\sim 160 \;\rm{ps}$ for hadronic showers above 1 GeV. The presented algorithm provides comparable reconstruction with the $E_{\mathrm{hit}}^2$ weighting strategy and can significantly improve the time resolution compared to a simple averaging of the fast component of the time spectrum. The effects of three detector configurations are also quantified in this study. ToF resolution depends linearly on the timing resolution of a single silicon sensor and improves statistically with increasing incident particle energy. The timing layers at depth of $6\sim 9$ radiation lengths provide higher timing performance for EM showers. A clustering algorithm that vetoes isolated hits improves ToF resolution.
format Preprint
id arxiv_https___arxiv_org_abs_2209_02932
institution arXiv
publishDate 2022
record_format arxiv
spellingShingle Cluster time measurement with CEPC calorimeter
Che, Yuzhi
Boudry, Vincent
Videau, Henri
He, Muchen
Ruan, Manqi
Instrumentation and Detectors
High Energy Physics - Experiment
We have developed an algorithm dedicated to timing reconstruction in highly granular calorimeters(HGC). The performance of this algorithm is evaluated on an electromagnetic calorimeter (ECAL) with geometries comparable to the electromagnetic compartment (CE-E) of the CMS endcap calorimeter upgrade at HL-LHC and conceptual Particle Flow oriented ECAL's for future Higgs factories. The time response of individual channel is parameterized according to the CMS experimental result. The particle Time-of-Flight (ToF) can be measured with a resolution of $5\sim20 \;\rm{ps}$ for electromagnetic (EM) showers and $80\sim 160 \;\rm{ps}$ for hadronic showers above 1 GeV. The presented algorithm provides comparable reconstruction with the $E_{\mathrm{hit}}^2$ weighting strategy and can significantly improve the time resolution compared to a simple averaging of the fast component of the time spectrum. The effects of three detector configurations are also quantified in this study. ToF resolution depends linearly on the timing resolution of a single silicon sensor and improves statistically with increasing incident particle energy. The timing layers at depth of $6\sim 9$ radiation lengths provide higher timing performance for EM showers. A clustering algorithm that vetoes isolated hits improves ToF resolution.
title Cluster time measurement with CEPC calorimeter
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2209.02932