A new sensing paradigm for the vibroacoustic detection of pedicle screw loosening

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Seibold, Matthias, Sigrist, Bastian, Götschi, Tobias, Widmer, Jonas, Hodel, Sandro, Farshad, Mazda, Navab, Nassir, Fürnstahl, Philipp, Laux, Christoph J.
Formato: Preprint
Publicado: 2022
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866917916952231936
author Seibold, Matthias
Sigrist, Bastian
Götschi, Tobias
Widmer, Jonas
Hodel, Sandro
Farshad, Mazda
Navab, Nassir
Fürnstahl, Philipp
Laux, Christoph J.
author_facet Seibold, Matthias
Sigrist, Bastian
Götschi, Tobias
Widmer, Jonas
Hodel, Sandro
Farshad, Mazda
Navab, Nassir
Fürnstahl, Philipp
Laux, Christoph J.
contents There is an unmet clinical need for developing novel methods to complement and replace the current radiation-emitting imaging-based methods for the detection of loose pedicle screws as a complication after spinal fusion surgery which fail to identify a substantial amount of loose implants. In this work, we propose a new methodology and paradigm for the radiation-free, non-destructive, and easy-to-integrate detection of pedicle screw loosening based on vibroacoustic sensing. Furthermore, we propose a novel simulation technique for pedicle screw loosening, which is biomechanically validated. For the detection of a loose implant, we excite the vertebra of interest with a sine sweep vibration at the spinous process and attach a custom highly-sensitive piezo contact microphone to the screw head to capture the propagated vibration characteristics which are analyzed using a detection pipeline based on spectrogram features and a SE-ResNet-18. To validate the proposed approach, we conducted experiments using four human cadaveric lumbar spine specimens and evaluate our algorithm in a cross validation experiment. Our method reaches a sensitivity of 91.50 +- 6.58% and a specificity of 91.10 +- 2.27%. The proposed system shows great potentials for the development of alternative assessment methods for implant loosening based on vibroacoustic sensing.
format Preprint
id arxiv_https___arxiv_org_abs_2210_16170
institution arXiv
publishDate 2022
record_format arxiv
spellingShingle A new sensing paradigm for the vibroacoustic detection of pedicle screw loosening
Seibold, Matthias
Sigrist, Bastian
Götschi, Tobias
Widmer, Jonas
Hodel, Sandro
Farshad, Mazda
Navab, Nassir
Fürnstahl, Philipp
Laux, Christoph J.
Medical Physics
There is an unmet clinical need for developing novel methods to complement and replace the current radiation-emitting imaging-based methods for the detection of loose pedicle screws as a complication after spinal fusion surgery which fail to identify a substantial amount of loose implants. In this work, we propose a new methodology and paradigm for the radiation-free, non-destructive, and easy-to-integrate detection of pedicle screw loosening based on vibroacoustic sensing. Furthermore, we propose a novel simulation technique for pedicle screw loosening, which is biomechanically validated. For the detection of a loose implant, we excite the vertebra of interest with a sine sweep vibration at the spinous process and attach a custom highly-sensitive piezo contact microphone to the screw head to capture the propagated vibration characteristics which are analyzed using a detection pipeline based on spectrogram features and a SE-ResNet-18. To validate the proposed approach, we conducted experiments using four human cadaveric lumbar spine specimens and evaluate our algorithm in a cross validation experiment. Our method reaches a sensitivity of 91.50 +- 6.58% and a specificity of 91.10 +- 2.27%. The proposed system shows great potentials for the development of alternative assessment methods for implant loosening based on vibroacoustic sensing.
title A new sensing paradigm for the vibroacoustic detection of pedicle screw loosening
topic Medical Physics
url https://arxiv.org/abs/2210.16170