The Effectiveness of a Simple Helmholtz coil-like Magnetic Shield at Reducing X-ray-like Background in Space-based X-ray Detectors

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Davis, Christopher S. W., Hall, David
Natura: Preprint
Pubblicazione: 2022
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866911869802905600
author Davis, Christopher S. W.
Hall, David
author_facet Davis, Christopher S. W.
Hall, David
contents Both active and passive magnetic shielding have been used extensively during past and current X-ray astronomy missions to shield detectors from soft protons and electrons entering through telescope optics. However, simulations performed throughout the past decade have discovered that a significant proportion of X-ray-like background originates from secondary electrons produced in spacecraft shielding surrounding X-ray detectors, which hit detectors isotropically from all directions. Here, the results from Geant4 simulations of a simple Helmholtz coil-like magnetic field surrounding a detector are presented, and it is found that a Helmholtz coil-like magnetic field is extremely effective at preventing secondary electrons from reaching the detector. This magnetic shielding method could remove almost all background associated with both backscattering electrons and fully absorbed soft electrons, which together are expected to account for approximately two thirds of the expected off-axis background in silicon-based X-ray detectors of several hundred microns in thickness. The magnetic field structure necessary for doing this could easily be produced using a set of solenoids or neodymium magnets providing that power requirements can be sufficiently optimised or neodymium fluorescence lines can be sufficiently attenuated, respectively.
format Preprint
id arxiv_https___arxiv_org_abs_2212_06974
institution arXiv
publishDate 2022
record_format arxiv
spellingShingle The Effectiveness of a Simple Helmholtz coil-like Magnetic Shield at Reducing X-ray-like Background in Space-based X-ray Detectors
Davis, Christopher S. W.
Hall, David
Instrumentation and Detectors
Both active and passive magnetic shielding have been used extensively during past and current X-ray astronomy missions to shield detectors from soft protons and electrons entering through telescope optics. However, simulations performed throughout the past decade have discovered that a significant proportion of X-ray-like background originates from secondary electrons produced in spacecraft shielding surrounding X-ray detectors, which hit detectors isotropically from all directions. Here, the results from Geant4 simulations of a simple Helmholtz coil-like magnetic field surrounding a detector are presented, and it is found that a Helmholtz coil-like magnetic field is extremely effective at preventing secondary electrons from reaching the detector. This magnetic shielding method could remove almost all background associated with both backscattering electrons and fully absorbed soft electrons, which together are expected to account for approximately two thirds of the expected off-axis background in silicon-based X-ray detectors of several hundred microns in thickness. The magnetic field structure necessary for doing this could easily be produced using a set of solenoids or neodymium magnets providing that power requirements can be sufficiently optimised or neodymium fluorescence lines can be sufficiently attenuated, respectively.
title The Effectiveness of a Simple Helmholtz coil-like Magnetic Shield at Reducing X-ray-like Background in Space-based X-ray Detectors
topic Instrumentation and Detectors
url https://arxiv.org/abs/2212.06974