Diffuse Maxwellian illumination for safe wide-field retinal Doppler holography

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Bratasz, Zofia, Martinache, Olivier, Blazy, Yohan, Denis, Angèle, Auffret, Coline, Huignard, Jean-Pierre, Rossi, Ethan, Chhablani, Jay, Sahel, José-Alain, Bonnin, Sophie, Hage, Rabih, Koskas, Patricia, Gatinel, Damien, Vignal, Catherine, Yavchitz, Amelie, Vasseur, Vivien, Tadayoni, Ramin, Ducloux, Claire, Ortoli, Manon, Tordjman, Marvin, Tick, Sarah, Mrejen, Sarah, Paques, Michel, Atlan, Michael
Formato: Preprint
Publicado: 2022
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866910222732230656
author Bratasz, Zofia
Martinache, Olivier
Blazy, Yohan
Denis, Angèle
Auffret, Coline
Huignard, Jean-Pierre
Rossi, Ethan
Chhablani, Jay
Sahel, José-Alain
Bonnin, Sophie
Hage, Rabih
Koskas, Patricia
Gatinel, Damien
Vignal, Catherine
Yavchitz, Amelie
Vasseur, Vivien
Tadayoni, Ramin
Ducloux, Claire
Ortoli, Manon
Tordjman, Marvin
Tick, Sarah
Mrejen, Sarah
Paques, Michel
Atlan, Michael
author_facet Bratasz, Zofia
Martinache, Olivier
Blazy, Yohan
Denis, Angèle
Auffret, Coline
Huignard, Jean-Pierre
Rossi, Ethan
Chhablani, Jay
Sahel, José-Alain
Bonnin, Sophie
Hage, Rabih
Koskas, Patricia
Gatinel, Damien
Vignal, Catherine
Yavchitz, Amelie
Vasseur, Vivien
Tadayoni, Ramin
Ducloux, Claire
Ortoli, Manon
Tordjman, Marvin
Tick, Sarah
Mrejen, Sarah
Paques, Michel
Atlan, Michael
contents We report a diffuse Maxwellian illumination scheme for wide-field retinal laser Doppler holography. Inserting an engineered diffuser in the illumination arm transforms a spatially concentrated near-infrared laser focus into an angularly diversified illumination pattern, thereby reducing local irradiance near the anterior segment while preserving coherent interferometric detection. This configuration allows the eyepiece to be positioned closer to the cornea, increasing the digitally reconstructed retinal field of view without producing a localized corneal hot spot. We compare three illumination geometries: focused non-diffuse illumination, diffuse illumination at the same cornea--eyepiece distance, and diffuse Maxwellian illumination. Diffuse Maxwellian illumination expands the retinal field of view while preserving Doppler contrast in broad and high-frequency fluctuation bands. Light-hazard assessment is limited to the current ophthalmic standards ISO 15004-2:2024 and ANSI Z80.36-2021. Based on measured beam profiles, the recommended operating power at 852 nm is set by the most restrictive relevant exposure condition among the assessed anterior-segment, iris, and retinal limits. These results support diffuse illumination as a practical route toward safer, non-mydriatic, wide-field Doppler holography of the human retina.
format Preprint
id arxiv_https___arxiv_org_abs_2212_13347
institution arXiv
publishDate 2022
record_format arxiv
spellingShingle Diffuse Maxwellian illumination for safe wide-field retinal Doppler holography
Bratasz, Zofia
Martinache, Olivier
Blazy, Yohan
Denis, Angèle
Auffret, Coline
Huignard, Jean-Pierre
Rossi, Ethan
Chhablani, Jay
Sahel, José-Alain
Bonnin, Sophie
Hage, Rabih
Koskas, Patricia
Gatinel, Damien
Vignal, Catherine
Yavchitz, Amelie
Vasseur, Vivien
Tadayoni, Ramin
Ducloux, Claire
Ortoli, Manon
Tordjman, Marvin
Tick, Sarah
Mrejen, Sarah
Paques, Michel
Atlan, Michael
Optics
Applied Physics
Medical Physics
We report a diffuse Maxwellian illumination scheme for wide-field retinal laser Doppler holography. Inserting an engineered diffuser in the illumination arm transforms a spatially concentrated near-infrared laser focus into an angularly diversified illumination pattern, thereby reducing local irradiance near the anterior segment while preserving coherent interferometric detection. This configuration allows the eyepiece to be positioned closer to the cornea, increasing the digitally reconstructed retinal field of view without producing a localized corneal hot spot. We compare three illumination geometries: focused non-diffuse illumination, diffuse illumination at the same cornea--eyepiece distance, and diffuse Maxwellian illumination. Diffuse Maxwellian illumination expands the retinal field of view while preserving Doppler contrast in broad and high-frequency fluctuation bands. Light-hazard assessment is limited to the current ophthalmic standards ISO 15004-2:2024 and ANSI Z80.36-2021. Based on measured beam profiles, the recommended operating power at 852 nm is set by the most restrictive relevant exposure condition among the assessed anterior-segment, iris, and retinal limits. These results support diffuse illumination as a practical route toward safer, non-mydriatic, wide-field Doppler holography of the human retina.
title Diffuse Maxwellian illumination for safe wide-field retinal Doppler holography
topic Optics
Applied Physics
Medical Physics
url https://arxiv.org/abs/2212.13347