Neutron capture-induced nuclear recoils as background for CE$ν$NS~measurements at reactors

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Biffl, A. J., Gevorgian, A., Harris, K., Villano, A. N.
Format: Preprint
Published: 2022
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866909138612649984
author Biffl, A. J.
Gevorgian, A.
Harris, K.
Villano, A. N.
author_facet Biffl, A. J.
Gevorgian, A.
Harris, K.
Villano, A. N.
contents Nuclear reactors represent a promising neutrino source for CE$ν$NS (coherent-elastic neutrino-nucleus scattering) searches. However, reactor sites also come with high ambient neutron flux. Neutron capture-induced nuclear recoils can create a spectrum that strongly overlaps the CE$ν$NS signal for recoils $\lesssim$\,100\,eV for nuclear reactor measurements in silicon or germanium detectors. This background can be particularly critical for low-power research reactors providing a moderate neutrino flux. In this work we quantify the impact of this background and show that, for a measurement 10\,m from a 1\,MW reactor, the effective thermal neutron flux should be kept below $\sim$~7$\times$~10$^{-4}$\,n/cm$^2$s so that the CE$ν$NS events can be measured at least at a 5$σ$ level with germanium detectors in 100~kg\,yr exposure time. This flux corresponds to 60\% of the sea-level flux but needs to be achieved in a nominally high-flux (reactor) environment. Improved detector resolution can help the measurements, but the thermal flux is the key parameter for the sensitivity of the experiment. For silicon detectors, the constraint is even stronger and thermal neutron fluxes must be near an order of magnitude lower. This constraint highlights the need of an effective thermal neutron mitigation strategy for future low threshold CE$ν$NS searches. In particular, the neutron capture-induced background can be efficiently reduced by active veto systems tagging the deexcitation gamma following the capture.
format Preprint
id arxiv_https___arxiv_org_abs_2212_14148
institution arXiv
publishDate 2022
record_format arxiv
spellingShingle Neutron capture-induced nuclear recoils as background for CE$ν$NS~measurements at reactors
Biffl, A. J.
Gevorgian, A.
Harris, K.
Villano, A. N.
High Energy Physics - Experiment
Nuclear Experiment
Instrumentation and Detectors
Nuclear reactors represent a promising neutrino source for CE$ν$NS (coherent-elastic neutrino-nucleus scattering) searches. However, reactor sites also come with high ambient neutron flux. Neutron capture-induced nuclear recoils can create a spectrum that strongly overlaps the CE$ν$NS signal for recoils $\lesssim$\,100\,eV for nuclear reactor measurements in silicon or germanium detectors. This background can be particularly critical for low-power research reactors providing a moderate neutrino flux. In this work we quantify the impact of this background and show that, for a measurement 10\,m from a 1\,MW reactor, the effective thermal neutron flux should be kept below $\sim$~7$\times$~10$^{-4}$\,n/cm$^2$s so that the CE$ν$NS events can be measured at least at a 5$σ$ level with germanium detectors in 100~kg\,yr exposure time. This flux corresponds to 60\% of the sea-level flux but needs to be achieved in a nominally high-flux (reactor) environment. Improved detector resolution can help the measurements, but the thermal flux is the key parameter for the sensitivity of the experiment. For silicon detectors, the constraint is even stronger and thermal neutron fluxes must be near an order of magnitude lower. This constraint highlights the need of an effective thermal neutron mitigation strategy for future low threshold CE$ν$NS searches. In particular, the neutron capture-induced background can be efficiently reduced by active veto systems tagging the deexcitation gamma following the capture.
title Neutron capture-induced nuclear recoils as background for CE$ν$NS~measurements at reactors
topic High Energy Physics - Experiment
Nuclear Experiment
Instrumentation and Detectors
url https://arxiv.org/abs/2212.14148