Greedy-optimized Approach for Interbeat Interval and Heart Rate Variability Daily Monitoring using Wearable PPG

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteur principal: Huang, Luffina C.
Format: Preprint
Publié: 2023
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866916207224946688
author Huang, Luffina C.
author_facet Huang, Luffina C.
contents Continuous monitoring of heart rate variability (HRV) provides insights in cardiovascular health. Wearable Photoplethysmography (PPG) assures convenient measurement of HRV. PPG, however, is susceptible to motion artifacts, considerably deteriorating the accuracy in estimation. In this study, a greedy-optimized approach is proposed for attaining high accuracy of interbeat intervals (IBIs) estimation from PPG signals collected during intensive daily activities. Utilizing the fact of continuity in heartbeats, the IBI estimation is converted into the shortest path problem in a directed acyclic graph, where candidate heartbeats from motion-contaminated PPG are regarded as vertices. The approach exploits a convex penalty function to optimize weight assignment in the shortest path calculation and a greedy fusion method to strengthen the selection process of optimal IBIs. Results achieve correlation of 0.96 for IBI estimation with the improvement of 58.4% in percentage error on the single-channel PPG signal from 2015 IEEE Signal Processing Cup. It also achieves correlation of 0.98 with percentage error of 2.2% in the two-channel PPG signal. Estimated and true HRV parameters are highly correlated. The approach is further validated on the PPG-DaLiA dataset with high correlation and low percentage error for IBI and HRV estimation in two daily activities, indicating the robustness of the proposed technique.
format Preprint
id arxiv_https___arxiv_org_abs_2301_02906
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle Greedy-optimized Approach for Interbeat Interval and Heart Rate Variability Daily Monitoring using Wearable PPG
Huang, Luffina C.
Signal Processing
Continuous monitoring of heart rate variability (HRV) provides insights in cardiovascular health. Wearable Photoplethysmography (PPG) assures convenient measurement of HRV. PPG, however, is susceptible to motion artifacts, considerably deteriorating the accuracy in estimation. In this study, a greedy-optimized approach is proposed for attaining high accuracy of interbeat intervals (IBIs) estimation from PPG signals collected during intensive daily activities. Utilizing the fact of continuity in heartbeats, the IBI estimation is converted into the shortest path problem in a directed acyclic graph, where candidate heartbeats from motion-contaminated PPG are regarded as vertices. The approach exploits a convex penalty function to optimize weight assignment in the shortest path calculation and a greedy fusion method to strengthen the selection process of optimal IBIs. Results achieve correlation of 0.96 for IBI estimation with the improvement of 58.4% in percentage error on the single-channel PPG signal from 2015 IEEE Signal Processing Cup. It also achieves correlation of 0.98 with percentage error of 2.2% in the two-channel PPG signal. Estimated and true HRV parameters are highly correlated. The approach is further validated on the PPG-DaLiA dataset with high correlation and low percentage error for IBI and HRV estimation in two daily activities, indicating the robustness of the proposed technique.
title Greedy-optimized Approach for Interbeat Interval and Heart Rate Variability Daily Monitoring using Wearable PPG
topic Signal Processing
url https://arxiv.org/abs/2301.02906