TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Shopa, R. Y., Baran, J., Klimaszewski, K., Krzemień, W., Raczyński, L., Wiślicki, W., Brzeziński, K., Chug, N., Coussat, A., Curceanu, C., Czerwiński, E., Dadgar, M., Dulski, K., Gajewski, J., Gajos, A., Hiesmayr, B. C., Valsan, E. Kavya, Korcyl, G., Kozik, T., Kumar, D., Kapłon, Ł., Moskal, G., Niedźwiecki, S., Panek, D., Parzych, S., del Rio, E. Pérez, Ruciński, A., Sharma, S., Shivani, Silarski, M., Skurzok, M., Stȩpień, E., Ardebili, F. Tayefi, Ardebili, K. Tayefi, Moskal, P.
Natura: Preprint
Pubblicazione: 2023
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866929451825102848
author Shopa, R. Y.
Baran, J.
Klimaszewski, K.
Krzemień, W.
Raczyński, L.
Wiślicki, W.
Brzeziński, K.
Chug, N.
Coussat, A.
Curceanu, C.
Czerwiński, E.
Dadgar, M.
Dulski, K.
Gajewski, J.
Gajos, A.
Hiesmayr, B. C.
Valsan, E. Kavya
Korcyl, G.
Kozik, T.
Kumar, D.
Kapłon, Ł.
Moskal, G.
Niedźwiecki, S.
Panek, D.
Parzych, S.
del Rio, E. Pérez
Ruciński, A.
Sharma, S.
Shivani
Silarski, M.
Skurzok, M.
Stȩpień, E.
Ardebili, F. Tayefi
Ardebili, K. Tayefi
Moskal, P.
author_facet Shopa, R. Y.
Baran, J.
Klimaszewski, K.
Krzemień, W.
Raczyński, L.
Wiślicki, W.
Brzeziński, K.
Chug, N.
Coussat, A.
Curceanu, C.
Czerwiński, E.
Dadgar, M.
Dulski, K.
Gajewski, J.
Gajos, A.
Hiesmayr, B. C.
Valsan, E. Kavya
Korcyl, G.
Kozik, T.
Kumar, D.
Kapłon, Ł.
Moskal, G.
Niedźwiecki, S.
Panek, D.
Parzych, S.
del Rio, E. Pérez
Ruciński, A.
Sharma, S.
Shivani
Silarski, M.
Skurzok, M.
Stȩpień, E.
Ardebili, F. Tayefi
Ardebili, K. Tayefi
Moskal, P.
contents We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (TB) Jagiellonian PET (J-PET) scanners. The method is applicable to generic cylindrical or modular multi-layer layouts and is extendable to multi-photon imaging. The system response matrix (SRM) is represented as a set of analytical functions, uniquely defined for each pair of plastic scintillator strips used for the detection. A realistic resolution model (RM) in detector space is derived from fitting the Monte Carlo simulated emissions and detections of annihilation photons on oblique transverse planes. Additional kernels embedded in SRM account for TOF, parallax effect and axial smearing. The algorithm was tested on datasets, simulated in GATE for the NEMA IEC and static XCAT phantoms inside a 24-module 2-layer TB J-PET. Compared to the reference TOF MLEM with none or a shift-invariant RM, an improvement was observed, as evaluated by the analysis of image quality, difference images and ground truth metrics. We also reconstructed the data with additive contributions, pre-filtered geometrically and with non-TOF scatter correction applied. Despite some deterioration, the obtained results still capitalise on the realistic RM with better edge preservation and superior ground truth metrics. The envisioned prospects of the TOF MLEM with analytical SRM include its application in multi-photon imaging and further upgrade to account for the non-collinearity, positron range and other factors.
format Preprint
id arxiv_https___arxiv_org_abs_2302_02967
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix
Shopa, R. Y.
Baran, J.
Klimaszewski, K.
Krzemień, W.
Raczyński, L.
Wiślicki, W.
Brzeziński, K.
Chug, N.
Coussat, A.
Curceanu, C.
Czerwiński, E.
Dadgar, M.
Dulski, K.
Gajewski, J.
Gajos, A.
Hiesmayr, B. C.
Valsan, E. Kavya
Korcyl, G.
Kozik, T.
Kumar, D.
Kapłon, Ł.
Moskal, G.
Niedźwiecki, S.
Panek, D.
Parzych, S.
del Rio, E. Pérez
Ruciński, A.
Sharma, S.
Shivani
Silarski, M.
Skurzok, M.
Stȩpień, E.
Ardebili, F. Tayefi
Ardebili, K. Tayefi
Moskal, P.
Medical Physics
Computational Physics
Instrumentation and Detectors
We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (TB) Jagiellonian PET (J-PET) scanners. The method is applicable to generic cylindrical or modular multi-layer layouts and is extendable to multi-photon imaging. The system response matrix (SRM) is represented as a set of analytical functions, uniquely defined for each pair of plastic scintillator strips used for the detection. A realistic resolution model (RM) in detector space is derived from fitting the Monte Carlo simulated emissions and detections of annihilation photons on oblique transverse planes. Additional kernels embedded in SRM account for TOF, parallax effect and axial smearing. The algorithm was tested on datasets, simulated in GATE for the NEMA IEC and static XCAT phantoms inside a 24-module 2-layer TB J-PET. Compared to the reference TOF MLEM with none or a shift-invariant RM, an improvement was observed, as evaluated by the analysis of image quality, difference images and ground truth metrics. We also reconstructed the data with additive contributions, pre-filtered geometrically and with non-TOF scatter correction applied. Despite some deterioration, the obtained results still capitalise on the realistic RM with better edge preservation and superior ground truth metrics. The envisioned prospects of the TOF MLEM with analytical SRM include its application in multi-photon imaging and further upgrade to account for the non-collinearity, positron range and other factors.
title TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix
topic Medical Physics
Computational Physics
Instrumentation and Detectors
url https://arxiv.org/abs/2302.02967