Nuclear quadrupole resonance spectroscopy with a femtotesla diamond magnetometer

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Silani, Yaser, Smits, Janis, Fescenko, Ilja, Malone, Michael W., McDowell, Andrew F., Jarmola, Andrey, Kehayias, Pauli, Richards, Bryan, Mosavian, Nazanin, Ristoff, Nathaniel, Acosta, Victor M.
Formato: Preprint
Publicado: 2023
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866916676614750208
author Silani, Yaser
Smits, Janis
Fescenko, Ilja
Malone, Michael W.
McDowell, Andrew F.
Jarmola, Andrey
Kehayias, Pauli
Richards, Bryan
Mosavian, Nazanin
Ristoff, Nathaniel
Acosta, Victor M.
author_facet Silani, Yaser
Smits, Janis
Fescenko, Ilja
Malone, Michael W.
McDowell, Andrew F.
Jarmola, Andrey
Kehayias, Pauli
Richards, Bryan
Mosavian, Nazanin
Ristoff, Nathaniel
Acosta, Victor M.
contents Sensitive Radio-Frequency (RF) magnetometers that can detect oscillating magnetic fields at the femtotesla level are needed for demanding applications such as Nuclear Quadrupole Resonance (NQR) spectroscopy. RF magnetometers based on Nitrogen-Vacancy (NV) centers in diamond have been predicted to offer femtotesla sensitivity, but published experiments have largely been limited to the picotesla level. Here, we demonstrate a femtotesla RF magnetometer based on an NV-doped diamond membrane inserted between two ferrite flux concentrators. The device operates in bias magnetic fields of 2-10 microtesla and provides a ~300-fold amplitude enhancement within the diamond for RF magnetic fields in the 0.07-3.6 MHz range. The magnetometer's sensitivity is ~70 fT s^{1/2} at 0.35 MHz, and the noise floor decreases to below 2 fT after 1 hour of acquisition. We used this sensor to detect the 3.6 MHz NQR signal of 14N in sodium nitrite powder at room temperature. NQR signals are amplified by a resonant RF coil wrapped around the sample, allowing for higher signal-to-noise ratio detection. The diamond RF magnetometer's recovery time after a strong RF pulse is ~35 us, limited by the coil ring-down time. The sodium-nitrite NQR frequency shifts linearly with temperature as -1.00 +/- 0.02 kHz/K, the magnetization dephasing time is T2* = 887 +/- 51 us, and a spin-lock spin-echo pulse sequence extends the signal lifetime to 332 +/- 23 ms, all consistent with coil-based NQR studies. Our results expand the sensitivity frontier of diamond magnetometers to the femtotesla range, with potential applications in security, medical imaging, and materials science.
format Preprint
id arxiv_https___arxiv_org_abs_2302_12401
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle Nuclear quadrupole resonance spectroscopy with a femtotesla diamond magnetometer
Silani, Yaser
Smits, Janis
Fescenko, Ilja
Malone, Michael W.
McDowell, Andrew F.
Jarmola, Andrey
Kehayias, Pauli
Richards, Bryan
Mosavian, Nazanin
Ristoff, Nathaniel
Acosta, Victor M.
Instrumentation and Detectors
Materials Science
Atomic Physics
Optics
Quantum Physics
Sensitive Radio-Frequency (RF) magnetometers that can detect oscillating magnetic fields at the femtotesla level are needed for demanding applications such as Nuclear Quadrupole Resonance (NQR) spectroscopy. RF magnetometers based on Nitrogen-Vacancy (NV) centers in diamond have been predicted to offer femtotesla sensitivity, but published experiments have largely been limited to the picotesla level. Here, we demonstrate a femtotesla RF magnetometer based on an NV-doped diamond membrane inserted between two ferrite flux concentrators. The device operates in bias magnetic fields of 2-10 microtesla and provides a ~300-fold amplitude enhancement within the diamond for RF magnetic fields in the 0.07-3.6 MHz range. The magnetometer's sensitivity is ~70 fT s^{1/2} at 0.35 MHz, and the noise floor decreases to below 2 fT after 1 hour of acquisition. We used this sensor to detect the 3.6 MHz NQR signal of 14N in sodium nitrite powder at room temperature. NQR signals are amplified by a resonant RF coil wrapped around the sample, allowing for higher signal-to-noise ratio detection. The diamond RF magnetometer's recovery time after a strong RF pulse is ~35 us, limited by the coil ring-down time. The sodium-nitrite NQR frequency shifts linearly with temperature as -1.00 +/- 0.02 kHz/K, the magnetization dephasing time is T2* = 887 +/- 51 us, and a spin-lock spin-echo pulse sequence extends the signal lifetime to 332 +/- 23 ms, all consistent with coil-based NQR studies. Our results expand the sensitivity frontier of diamond magnetometers to the femtotesla range, with potential applications in security, medical imaging, and materials science.
title Nuclear quadrupole resonance spectroscopy with a femtotesla diamond magnetometer
topic Instrumentation and Detectors
Materials Science
Atomic Physics
Optics
Quantum Physics
url https://arxiv.org/abs/2302.12401