Implementation and evaluation of a dynamic contrast enhanced mr perfusion protocol for glioblastoma using a 0.35T mri-Linac system

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Maziero, Danilo, Azzam, Gregory, de La Fuente, Macarena, Stoyanova, Radka, Ford, John Chetley, Mellon, Eric Albert
Format: Preprint
Veröffentlicht: 2023
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866909102817411072
author Maziero, Danilo
Azzam, Gregory
de La Fuente, Macarena
Stoyanova, Radka
Ford, John Chetley
Mellon, Eric Albert
author_facet Maziero, Danilo
Azzam, Gregory
de La Fuente, Macarena
Stoyanova, Radka
Ford, John Chetley
Mellon, Eric Albert
contents MRI-linear accelerator (MRI-Linac) systems allow for daily tracking of MRI changes during radiotherapy (RT). Since one common MRI-Linac operates at 0.35T, there are efforts towards developing protocols at that field strength. In this study we demonstrate the implementation of a post-contrast 3DT1-weighted (3DT1w) and dynamic contrast enhancement (DCE) protocol to assess glioblastoma response to RT using a 0.35T MRI-Linac. The protocol implemented was used to acquire 3DT1w and DCE data from a flow phantom and two patients with glioblastoma (a responder and a non-responder) who underwent RT on a 0.35T-MRI-Linac. The detection of post-contrast enhanced volumes was evaluated by comparing the 3DT1w images from the 0.35T-MRI-Linac to images obtained using a 3T-standalone scanner. The DCE data were tested temporally and spatially using data from the flow phantom and patients. K-trans maps were derived from DCE at three time points (a week before treatment: Pre RT, four weeks through treatment: Mid RT, and three weeks after treatment: Post RT) and were validated with patients treatment outcomes. The 3D-T1 contrast enhancement volumes were visually and volumetrically similar (+/- 0.6-3.6%) between 0.35T MRI-Linac and 3T. DCE images showed temporal stability, and associated K-trans maps were consistent with patient response to treatment. On average, K-trans values showed a 54% decrease and 8.6% increase for a responder and non-responder respectively when Pre RT and Mid RT images were compared. Our findings support the feasibility of obtaining post-contrast 3DT1w and DCE data from patients with glioblastoma using a 0.35T MRI-Linac system.
format Preprint
id arxiv_https___arxiv_org_abs_2304_09128
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle Implementation and evaluation of a dynamic contrast enhanced mr perfusion protocol for glioblastoma using a 0.35T mri-Linac system
Maziero, Danilo
Azzam, Gregory
de La Fuente, Macarena
Stoyanova, Radka
Ford, John Chetley
Mellon, Eric Albert
Medical Physics
MRI-linear accelerator (MRI-Linac) systems allow for daily tracking of MRI changes during radiotherapy (RT). Since one common MRI-Linac operates at 0.35T, there are efforts towards developing protocols at that field strength. In this study we demonstrate the implementation of a post-contrast 3DT1-weighted (3DT1w) and dynamic contrast enhancement (DCE) protocol to assess glioblastoma response to RT using a 0.35T MRI-Linac. The protocol implemented was used to acquire 3DT1w and DCE data from a flow phantom and two patients with glioblastoma (a responder and a non-responder) who underwent RT on a 0.35T-MRI-Linac. The detection of post-contrast enhanced volumes was evaluated by comparing the 3DT1w images from the 0.35T-MRI-Linac to images obtained using a 3T-standalone scanner. The DCE data were tested temporally and spatially using data from the flow phantom and patients. K-trans maps were derived from DCE at three time points (a week before treatment: Pre RT, four weeks through treatment: Mid RT, and three weeks after treatment: Post RT) and were validated with patients treatment outcomes. The 3D-T1 contrast enhancement volumes were visually and volumetrically similar (+/- 0.6-3.6%) between 0.35T MRI-Linac and 3T. DCE images showed temporal stability, and associated K-trans maps were consistent with patient response to treatment. On average, K-trans values showed a 54% decrease and 8.6% increase for a responder and non-responder respectively when Pre RT and Mid RT images were compared. Our findings support the feasibility of obtaining post-contrast 3DT1w and DCE data from patients with glioblastoma using a 0.35T MRI-Linac system.
title Implementation and evaluation of a dynamic contrast enhanced mr perfusion protocol for glioblastoma using a 0.35T mri-Linac system
topic Medical Physics
url https://arxiv.org/abs/2304.09128