Simulation of a Compton-based detector for low-dose high-resolution time-of-flight positron emission tomography

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Domurat-Sousa, Kepler, Poe, Cameron M., McDaniel, Maya S., Spieglan, Eric, Shida, Joao F., Angelico, Evan, Adams, Bernhard W., La Riviere, Patrick J., Frisch, Henry J., Squires, Allison H.
Format: Preprint
Published: 2023
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866929196310200320
author Domurat-Sousa, Kepler
Poe, Cameron M.
McDaniel, Maya S.
Spieglan, Eric
Shida, Joao F.
Angelico, Evan
Adams, Bernhard W.
La Riviere, Patrick J.
Frisch, Henry J.
Squires, Allison H.
author_facet Domurat-Sousa, Kepler
Poe, Cameron M.
McDaniel, Maya S.
Spieglan, Eric
Shida, Joao F.
Angelico, Evan
Adams, Bernhard W.
La Riviere, Patrick J.
Frisch, Henry J.
Squires, Allison H.
contents Two major challenges in time-of-flight positron emission tomography (TOF-PET) are low spatial resolution and high radioactive dose to the patient, both of which result from limitations in detection technology rather than fundamental physics. A new type of TOF-PET detector employing low-atomic number (low-Z) scintillation media and large-area, high-resolution photodetectors to record Compton scattering locations in the detector has been proposed as a promising alternative, but the minimum technical requirements for such a system have not yet been established. Here we present a simulation study evaluating the potential of a proposed low-Z detection medium, linear alkylbenzene (LAB) doped with a switchable molecular recorder, for next-generation TOF-PET detection. We developed a custom Monte Carlo simulation of full-body TOF-PET using the TOPAS Geant4 software package. By quantifying contributions and tradeoffs for energy, spatial, and timing resolution of the detector, we show that at reasonable combination of specifications, our likelihood-based identification of pairs of first interaction locations in the simulated detector identifies 87.1% of pairs with zero or negligible error, and correctly rejects 90% of all in-patient scatters. The same specifications give TOF-PET sensitivity of ~66.7% and PSF width 4.6 mm with clear contrast. A detector with these specifications provides a clear image of a brain phantom simulated at less than 1% of a standard radiotracer dose.
format Preprint
id arxiv_https___arxiv_org_abs_2305_07173
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle Simulation of a Compton-based detector for low-dose high-resolution time-of-flight positron emission tomography
Domurat-Sousa, Kepler
Poe, Cameron M.
McDaniel, Maya S.
Spieglan, Eric
Shida, Joao F.
Angelico, Evan
Adams, Bernhard W.
La Riviere, Patrick J.
Frisch, Henry J.
Squires, Allison H.
Medical Physics
High Energy Physics - Experiment
Two major challenges in time-of-flight positron emission tomography (TOF-PET) are low spatial resolution and high radioactive dose to the patient, both of which result from limitations in detection technology rather than fundamental physics. A new type of TOF-PET detector employing low-atomic number (low-Z) scintillation media and large-area, high-resolution photodetectors to record Compton scattering locations in the detector has been proposed as a promising alternative, but the minimum technical requirements for such a system have not yet been established. Here we present a simulation study evaluating the potential of a proposed low-Z detection medium, linear alkylbenzene (LAB) doped with a switchable molecular recorder, for next-generation TOF-PET detection. We developed a custom Monte Carlo simulation of full-body TOF-PET using the TOPAS Geant4 software package. By quantifying contributions and tradeoffs for energy, spatial, and timing resolution of the detector, we show that at reasonable combination of specifications, our likelihood-based identification of pairs of first interaction locations in the simulated detector identifies 87.1% of pairs with zero or negligible error, and correctly rejects 90% of all in-patient scatters. The same specifications give TOF-PET sensitivity of ~66.7% and PSF width 4.6 mm with clear contrast. A detector with these specifications provides a clear image of a brain phantom simulated at less than 1% of a standard radiotracer dose.
title Simulation of a Compton-based detector for low-dose high-resolution time-of-flight positron emission tomography
topic Medical Physics
High Energy Physics - Experiment
url https://arxiv.org/abs/2305.07173