Modelling the response of a CsI(Tl)-PiN photodiode Microscintillator Detector

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Tabbett, Justin, Aplin, Karen L.
Format: Preprint
Veröffentlicht: 2023
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866911767150460928
author Tabbett, Justin
Aplin, Karen L.
author_facet Tabbett, Justin
Aplin, Karen L.
contents The full instrument response of a superminiaturised CsI(Tl)-PiN photodiode radioactivity detector, intended for deployment on a meteorological radiosonde, has been modelled by combining a physics-based model of the sensor with the detector circuit response, obtained via an LTspice simulation. The model uses the incident energy of a gamma ray as an input, and produces the pulse expected from the detector. The detector response was verified by comparing the simulated energy calibration with a laboratory source. The measurement circuit is found to control the minimum detectable energy of 26 keV, and the maximum detectable energy is ~10 MeV. The energy sensitivity of the PiN detector is 0.29 +- 0.02 mV/keV in the 0-800 keV range. The simulation and laboratory calibrations were consistent to better than 5% over the calibration range of the instrument.
format Preprint
id arxiv_https___arxiv_org_abs_2307_03029
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle Modelling the response of a CsI(Tl)-PiN photodiode Microscintillator Detector
Tabbett, Justin
Aplin, Karen L.
Instrumentation and Detectors
The full instrument response of a superminiaturised CsI(Tl)-PiN photodiode radioactivity detector, intended for deployment on a meteorological radiosonde, has been modelled by combining a physics-based model of the sensor with the detector circuit response, obtained via an LTspice simulation. The model uses the incident energy of a gamma ray as an input, and produces the pulse expected from the detector. The detector response was verified by comparing the simulated energy calibration with a laboratory source. The measurement circuit is found to control the minimum detectable energy of 26 keV, and the maximum detectable energy is ~10 MeV. The energy sensitivity of the PiN detector is 0.29 +- 0.02 mV/keV in the 0-800 keV range. The simulation and laboratory calibrations were consistent to better than 5% over the calibration range of the instrument.
title Modelling the response of a CsI(Tl)-PiN photodiode Microscintillator Detector
topic Instrumentation and Detectors
url https://arxiv.org/abs/2307.03029