contents We report initial research to develop a compact and practical primary thermometer based on Doppler broadening thermometry (DBT). The DBT sensor uses an intrinsic property of thermalized atoms, namely, the Doppler width of a spectral line characteristic of the atoms being probed. The DBT sensor, being founded on a primary thermometry approach, requires no calibration or reference, and so in principle could achieve reliable long-term in-situ thermodynamic temperature measurement. Here we describe our approach and report on initial proof-of-concept investigations with alkali metal vapour cells. Our focus is to develop long-term stable thermometers based on DBT that can be used to reliably measure temperatures for long periods and in environments where sensor retrieval for re-calibration is impractical such as in nuclear waste storage facilities.
format Preprint
id arxiv_https___arxiv_org_abs_2307_06229
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle Practical Doppler broadening thermometry
Agnew, Nicola
Machin, Graham
Riis, Erling
Arnold, Aidan S.
Atomic Physics
Applied Physics
We report initial research to develop a compact and practical primary thermometer based on Doppler broadening thermometry (DBT). The DBT sensor uses an intrinsic property of thermalized atoms, namely, the Doppler width of a spectral line characteristic of the atoms being probed. The DBT sensor, being founded on a primary thermometry approach, requires no calibration or reference, and so in principle could achieve reliable long-term in-situ thermodynamic temperature measurement. Here we describe our approach and report on initial proof-of-concept investigations with alkali metal vapour cells. Our focus is to develop long-term stable thermometers based on DBT that can be used to reliably measure temperatures for long periods and in environments where sensor retrieval for re-calibration is impractical such as in nuclear waste storage facilities.
title Practical Doppler broadening thermometry
topic Atomic Physics
Applied Physics
url https://arxiv.org/abs/2307.06229