Integrating microdosimetric in vitro RBE models for particle therapy into TOPAS MC using the MicrOdosimetry-based modeling for RBE Assessment (MONAS) tool

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Cartechini, Giorgio, Missiaggia, Marta, Scifoni, Emanuele, La Tessa, Chiara, Cordoni, Francesco G.
Formato: Preprint
Publicado: 2023
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866917212834496512
author Cartechini, Giorgio
Missiaggia, Marta
Scifoni, Emanuele
La Tessa, Chiara
Cordoni, Francesco G.
author_facet Cartechini, Giorgio
Missiaggia, Marta
Scifoni, Emanuele
La Tessa, Chiara
Cordoni, Francesco G.
contents We present MONAS (MicrOdosimetry-based modelliNg for relative biological effectiveness (RBE) ASsessment) toolkit. MONAS is a TOPAS Monte Carlo extension, that combines simulations of microdosimetric distributions with radiobiological microdosimetry-based models for predicting cell survival curves and dose-dependent RBE. MONAS expands TOPAS microdosimetric extension, by including novel specific energy scorers. These spectra are used as physical input to three different formulations of the Microdosimetric Kinetic Model (MKM), and to the Generalized Stochastic Microdosimetric Model (GSM2), to predict dose-dependent cell survival fraction and RBE. MONAS predictions are then validated against experimental microdosimetric spectra and in vitro survival fraction data. We present two different applications of the code: i) the depth-RBE curve calculation from a passively scattered proton SOBP, and ii) the calculation of the 3D RBE distribution on a real head and neck patient geometry treated with protons. MONAS can estimate dose dependent RBE and cell survival curves from experimentally validated microdosimetric spectra with four clinically relevant radiobiological models. From the radiobiological characterization of a proton SOBP field, we observe the well-known trend of increasing RBE values at the distal edge of the radiation field. The 3D RBE map calculated confirmed the trend observed in the analysis of the SOBP, with the highest RBE values found in the distal edge of the target. MONAS extension offers a comprehensive microdosimetry-based framework for assessing the biological effects of particle radiation in both research and clinical environments, contributing to bridging the gap between a microdosimetric description of the radiation field and its application in proton therapy treatment with variable RBE.
format Preprint
id arxiv_https___arxiv_org_abs_2307_08791
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle Integrating microdosimetric in vitro RBE models for particle therapy into TOPAS MC using the MicrOdosimetry-based modeling for RBE Assessment (MONAS) tool
Cartechini, Giorgio
Missiaggia, Marta
Scifoni, Emanuele
La Tessa, Chiara
Cordoni, Francesco G.
Medical Physics
We present MONAS (MicrOdosimetry-based modelliNg for relative biological effectiveness (RBE) ASsessment) toolkit. MONAS is a TOPAS Monte Carlo extension, that combines simulations of microdosimetric distributions with radiobiological microdosimetry-based models for predicting cell survival curves and dose-dependent RBE. MONAS expands TOPAS microdosimetric extension, by including novel specific energy scorers. These spectra are used as physical input to three different formulations of the Microdosimetric Kinetic Model (MKM), and to the Generalized Stochastic Microdosimetric Model (GSM2), to predict dose-dependent cell survival fraction and RBE. MONAS predictions are then validated against experimental microdosimetric spectra and in vitro survival fraction data. We present two different applications of the code: i) the depth-RBE curve calculation from a passively scattered proton SOBP, and ii) the calculation of the 3D RBE distribution on a real head and neck patient geometry treated with protons. MONAS can estimate dose dependent RBE and cell survival curves from experimentally validated microdosimetric spectra with four clinically relevant radiobiological models. From the radiobiological characterization of a proton SOBP field, we observe the well-known trend of increasing RBE values at the distal edge of the radiation field. The 3D RBE map calculated confirmed the trend observed in the analysis of the SOBP, with the highest RBE values found in the distal edge of the target. MONAS extension offers a comprehensive microdosimetry-based framework for assessing the biological effects of particle radiation in both research and clinical environments, contributing to bridging the gap between a microdosimetric description of the radiation field and its application in proton therapy treatment with variable RBE.
title Integrating microdosimetric in vitro RBE models for particle therapy into TOPAS MC using the MicrOdosimetry-based modeling for RBE Assessment (MONAS) tool
topic Medical Physics
url https://arxiv.org/abs/2307.08791