A High-Sensitivity Radon Emanation Detector System for Future Low-Background Experiments

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Wiebe, D., Lindemann, S., Schumann, M.
Format: Preprint
Publié: 2023
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866907777007353856
author Wiebe, D.
Lindemann, S.
Schumann, M.
author_facet Wiebe, D.
Lindemann, S.
Schumann, M.
contents Radioactive radon atoms originating from the long-lived primordial $^{238}\mathrm{U}$ and $^{232}\mathrm{Th}$ decay chains are constantly emanated from the surfaces of most materials. The radon atoms and their radioactive daughter isotopes can significantly contribute to the background of low-background experiments. The $^{222}\mathrm{Rn}$ progeny $^{214}\mathrm{Pb}$, for example, dominates the background of current liquid xenon-based direct dark matter detectors. We report on a new detector system to directly quantify the $^{222}\mathrm{Rn}$ surface emanation rate of materials. Using cryogenic physisorption traps, emanated radon atoms are transferred from an independent emanation vessel and concentrated within the dedicated detection vessel. The charged daughter isotopes are collected electrostatically on a silicon PIN photodiode to spectrometrically measure the alpha decays of $^{218}\mathrm{Po}$ and $^{214}\mathrm{Po}$. The overall detection efficiency is $\sim 36\,\%$ for both polonium channels. The radon emanation activity of the emanation vessel was measured to be $(0.16\pm 0.03)\,\mathrm{mBq}$, resulting in a detection sensitivity of $\sim 0.06\,\mathrm{mBq}$ at $90\,\%\,\mathrm{C.L.}$.
format Preprint
id arxiv_https___arxiv_org_abs_2309_04514
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle A High-Sensitivity Radon Emanation Detector System for Future Low-Background Experiments
Wiebe, D.
Lindemann, S.
Schumann, M.
Instrumentation and Detectors
Radioactive radon atoms originating from the long-lived primordial $^{238}\mathrm{U}$ and $^{232}\mathrm{Th}$ decay chains are constantly emanated from the surfaces of most materials. The radon atoms and their radioactive daughter isotopes can significantly contribute to the background of low-background experiments. The $^{222}\mathrm{Rn}$ progeny $^{214}\mathrm{Pb}$, for example, dominates the background of current liquid xenon-based direct dark matter detectors. We report on a new detector system to directly quantify the $^{222}\mathrm{Rn}$ surface emanation rate of materials. Using cryogenic physisorption traps, emanated radon atoms are transferred from an independent emanation vessel and concentrated within the dedicated detection vessel. The charged daughter isotopes are collected electrostatically on a silicon PIN photodiode to spectrometrically measure the alpha decays of $^{218}\mathrm{Po}$ and $^{214}\mathrm{Po}$. The overall detection efficiency is $\sim 36\,\%$ for both polonium channels. The radon emanation activity of the emanation vessel was measured to be $(0.16\pm 0.03)\,\mathrm{mBq}$, resulting in a detection sensitivity of $\sim 0.06\,\mathrm{mBq}$ at $90\,\%\,\mathrm{C.L.}$.
title A High-Sensitivity Radon Emanation Detector System for Future Low-Background Experiments
topic Instrumentation and Detectors
url https://arxiv.org/abs/2309.04514