Generation of photoionized plasmas in the laboratory of relevance to accretion-powered x-ray sources using keV line radiation

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Riley, D., Singh, R. L., White, S, Charlwood, M., Bailie, D., Hyland, C., Audet, T., Sarri, G., Kettle, B., Gribakin, G., Rose, S. J., Hill, E. G., Ferland, G. J., Williams, R. J. R., Keenan, F. P.
Formato: Preprint
Publicado: 2023
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866914719253659648
author Riley, D.
Singh, R. L.
White, S
Charlwood, M.
Bailie, D.
Hyland, C.
Audet, T.
Sarri, G.
Kettle, B.
Gribakin, G.
Rose, S. J.
Hill, E. G.
Ferland, G. J.
Williams, R. J. R.
Keenan, F. P.
author_facet Riley, D.
Singh, R. L.
White, S
Charlwood, M.
Bailie, D.
Hyland, C.
Audet, T.
Sarri, G.
Kettle, B.
Gribakin, G.
Rose, S. J.
Hill, E. G.
Ferland, G. J.
Williams, R. J. R.
Keenan, F. P.
contents We describe laboratory experiments to generate X-ray photoionized plasmas of relevance to accretion-powered X-ray sources such as neutron star binaries and quasars, with significant improvements over previous work. A key quantity is referenced, namely the photoionization parameter. This is normally meaningful in an astrophysical steady-state context, but is also commonly used in the literature as a figure of merit for laboratory experiments that are, of necessity, time-dependent. We demonstrate emission-weighted values of ξ > 50 ergcm/s using laser-plasma X-ray sources, with higher results at the centre of the plasma which are in the regime of interest for several astrophysical scenarios. Comparisons of laboratory experiments with astrophysical codes are always limited, principally by the many orders of magnitude differences in time and spatial scales, but also other plasma parameters. However useful checks on performance can often be made for a limited range of parameters. For example, we show that our use of a keV line source, rather than the quasi-blackbody radiation fields normally employed in such experiments, has allowed the generation of the ratio of inner-shell to outer-shell photoionization expected from a blackbody source with ~keV spectral temperature. We compare calculations from our in-house plasma modelling code with those from Cloudy and find moderately good agreement for the time evolution of both electron temperature and average ionisation. However, a comparison of code predictions for a K-beta argon X-ray spectrum with experimental data reveals that our Cloudy simulation overestimates the intensities of more highly ionised argon species. This is not totally surprising as the Cloudy model was generated for a single set of plasma conditions, while the experimental data are spatially integrated.
format Preprint
id arxiv_https___arxiv_org_abs_2309_07267
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle Generation of photoionized plasmas in the laboratory of relevance to accretion-powered x-ray sources using keV line radiation
Riley, D.
Singh, R. L.
White, S
Charlwood, M.
Bailie, D.
Hyland, C.
Audet, T.
Sarri, G.
Kettle, B.
Gribakin, G.
Rose, S. J.
Hill, E. G.
Ferland, G. J.
Williams, R. J. R.
Keenan, F. P.
High Energy Astrophysical Phenomena
Instrumentation and Methods for Astrophysics
We describe laboratory experiments to generate X-ray photoionized plasmas of relevance to accretion-powered X-ray sources such as neutron star binaries and quasars, with significant improvements over previous work. A key quantity is referenced, namely the photoionization parameter. This is normally meaningful in an astrophysical steady-state context, but is also commonly used in the literature as a figure of merit for laboratory experiments that are, of necessity, time-dependent. We demonstrate emission-weighted values of ξ > 50 ergcm/s using laser-plasma X-ray sources, with higher results at the centre of the plasma which are in the regime of interest for several astrophysical scenarios. Comparisons of laboratory experiments with astrophysical codes are always limited, principally by the many orders of magnitude differences in time and spatial scales, but also other plasma parameters. However useful checks on performance can often be made for a limited range of parameters. For example, we show that our use of a keV line source, rather than the quasi-blackbody radiation fields normally employed in such experiments, has allowed the generation of the ratio of inner-shell to outer-shell photoionization expected from a blackbody source with ~keV spectral temperature. We compare calculations from our in-house plasma modelling code with those from Cloudy and find moderately good agreement for the time evolution of both electron temperature and average ionisation. However, a comparison of code predictions for a K-beta argon X-ray spectrum with experimental data reveals that our Cloudy simulation overestimates the intensities of more highly ionised argon species. This is not totally surprising as the Cloudy model was generated for a single set of plasma conditions, while the experimental data are spatially integrated.
title Generation of photoionized plasmas in the laboratory of relevance to accretion-powered x-ray sources using keV line radiation
topic High Energy Astrophysical Phenomena
Instrumentation and Methods for Astrophysics
url https://arxiv.org/abs/2309.07267