A comparison of the neutron detection efficiency and response characteristics of two pixelated PSD-capable organic scintillator detectors with different photo-detection readout methods

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Balajthy, J., Marleau, P., Sweany, M.
Formato: Preprint
Publicado: 2023
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866916109603569664
author Balajthy, J.
Marleau, P.
Sweany, M.
author_facet Balajthy, J.
Marleau, P.
Sweany, M.
contents We characterize the performance of two pixelated neutron detectors: a PMT-based array that utilizes Anger logic for pixel identification and a SiPM-based array that employs individual pixel readout. The SiPM-based array offers improved performance over the previously developed PMT-based detector both in terms of uniformity and neutron detection efficiency. Each detector array uses PSD-capable plastic scintillator as a detection medium. We describe the calibration and neutron efficiency measurement of both detectors using a $^{137}$Cs source for energy calibration and a $^{252}$Cf source for calibration of the neutron response. We find that the intrinsic neutron detection efficiency of the SiPM-based array is ($30.2 \ \pm \ 1.7$)\%, which is almost twice that of the PMT-based array, which we measure to be ($16.9 \pm 0.2$)\%.
format Preprint
id arxiv_https___arxiv_org_abs_2309_12651
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle A comparison of the neutron detection efficiency and response characteristics of two pixelated PSD-capable organic scintillator detectors with different photo-detection readout methods
Balajthy, J.
Marleau, P.
Sweany, M.
Instrumentation and Detectors
Nuclear Experiment
We characterize the performance of two pixelated neutron detectors: a PMT-based array that utilizes Anger logic for pixel identification and a SiPM-based array that employs individual pixel readout. The SiPM-based array offers improved performance over the previously developed PMT-based detector both in terms of uniformity and neutron detection efficiency. Each detector array uses PSD-capable plastic scintillator as a detection medium. We describe the calibration and neutron efficiency measurement of both detectors using a $^{137}$Cs source for energy calibration and a $^{252}$Cf source for calibration of the neutron response. We find that the intrinsic neutron detection efficiency of the SiPM-based array is ($30.2 \ \pm \ 1.7$)\%, which is almost twice that of the PMT-based array, which we measure to be ($16.9 \pm 0.2$)\%.
title A comparison of the neutron detection efficiency and response characteristics of two pixelated PSD-capable organic scintillator detectors with different photo-detection readout methods
topic Instrumentation and Detectors
Nuclear Experiment
url https://arxiv.org/abs/2309.12651