First operation of an ACHINOS-equipped Spherical Proportional Counter with individual anode read-out

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Herd, D., Katsioulas, I., Knights, P., Manthos, I., Matthews, J., Millins, L., Neep, T., Nikolopoulos, K., Rogers, G.
Natura: Preprint
Pubblicazione: 2023
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866909076393295872
author Herd, D.
Katsioulas, I.
Knights, P.
Manthos, I.
Matthews, J.
Millins, L.
Neep, T.
Nikolopoulos, K.
Rogers, G.
author_facet Herd, D.
Katsioulas, I.
Knights, P.
Manthos, I.
Matthews, J.
Millins, L.
Neep, T.
Nikolopoulos, K.
Rogers, G.
contents The multi-anode sensor ACHINOS revolutionised the capabilities of the spherical proportional counter by enabling large-size, high-pressure, operation and TPC-like reconstruction capabilities through individual anode read-out. First measurements with an individually read out ACHINOS are performed, which enables improved calibration and response homogenisation. Experimental results demonstrating the improvement in energy resolution brought by the individual anode calibration are presented. These are complemented by detailed simulation studies on the effect of sensor design and manufacturing imperfections, and how they may be corrected both in hardware and analysis.
format Preprint
id arxiv_https___arxiv_org_abs_2309_15066
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle First operation of an ACHINOS-equipped Spherical Proportional Counter with individual anode read-out
Herd, D.
Katsioulas, I.
Knights, P.
Manthos, I.
Matthews, J.
Millins, L.
Neep, T.
Nikolopoulos, K.
Rogers, G.
Instrumentation and Detectors
The multi-anode sensor ACHINOS revolutionised the capabilities of the spherical proportional counter by enabling large-size, high-pressure, operation and TPC-like reconstruction capabilities through individual anode read-out. First measurements with an individually read out ACHINOS are performed, which enables improved calibration and response homogenisation. Experimental results demonstrating the improvement in energy resolution brought by the individual anode calibration are presented. These are complemented by detailed simulation studies on the effect of sensor design and manufacturing imperfections, and how they may be corrected both in hardware and analysis.
title First operation of an ACHINOS-equipped Spherical Proportional Counter with individual anode read-out
topic Instrumentation and Detectors
url https://arxiv.org/abs/2309.15066