Forced oscillation source localization from generator measurements

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Tyloo, Melvyn, Vuffray, Marc, Lokhov, Andrey Y.
Format: Preprint
Published: 2023
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866929286316818432
author Tyloo, Melvyn
Vuffray, Marc
Lokhov, Andrey Y.
author_facet Tyloo, Melvyn
Vuffray, Marc
Lokhov, Andrey Y.
contents Malfunctioning equipment, erroneous operating conditions or periodic load variations can cause periodic disturbances that would persist over time, creating an undesirable transfer of energy across the system -- an effect referred to as forced oscillations. Wide-area oscillations may damage assets, trigger inadvertent tripping or control actions, and be the cause of equipment failure. Unfortunately, for wide-area oscillations, the location, frequency, and amplitude of these forced oscillations may be hard to determine. Recently, a data-driven maximum-likelihood-based method was proposed to perform source localization in transmission grids under wide-area response scenarios. However, this method relies on full PMU coverage and all buses having inertia and damping. Here, we extend this method to realistic scenarios which includes buses without inertia or dumping, such as passive loads and inverter-based generators. Incorporating Kron reduction directly into the maximum likelihood estimator, we are able to identify the location and frequency of forcing applied at both traditional generators and loads.
format Preprint
id arxiv_https___arxiv_org_abs_2310_00458
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle Forced oscillation source localization from generator measurements
Tyloo, Melvyn
Vuffray, Marc
Lokhov, Andrey Y.
Systems and Control
Adaptation and Self-Organizing Systems
Malfunctioning equipment, erroneous operating conditions or periodic load variations can cause periodic disturbances that would persist over time, creating an undesirable transfer of energy across the system -- an effect referred to as forced oscillations. Wide-area oscillations may damage assets, trigger inadvertent tripping or control actions, and be the cause of equipment failure. Unfortunately, for wide-area oscillations, the location, frequency, and amplitude of these forced oscillations may be hard to determine. Recently, a data-driven maximum-likelihood-based method was proposed to perform source localization in transmission grids under wide-area response scenarios. However, this method relies on full PMU coverage and all buses having inertia and damping. Here, we extend this method to realistic scenarios which includes buses without inertia or dumping, such as passive loads and inverter-based generators. Incorporating Kron reduction directly into the maximum likelihood estimator, we are able to identify the location and frequency of forcing applied at both traditional generators and loads.
title Forced oscillation source localization from generator measurements
topic Systems and Control
Adaptation and Self-Organizing Systems
url https://arxiv.org/abs/2310.00458