Spot-Based Measurement of the Brighter-Fatter Effect on a Roman Space Telescope H4RG Detector and Comparison with Flat-Field Data

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Malagón, Andrés A. Plazas, Shapiro, Charles, Choi, Ami, Hirata, Chris
Format: Preprint
Veröffentlicht: 2023
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866910387524337664
author Malagón, Andrés A. Plazas
Shapiro, Charles
Choi, Ami
Hirata, Chris
author_facet Malagón, Andrés A. Plazas
Shapiro, Charles
Choi, Ami
Hirata, Chris
contents We present the measurement and characterization of the brighter-fatter effect (BFE) on a NASA Roman Space Telescope development Teledyne H4RG-10 near-infrared detector using laboratory measurements with projected point sources. After correcting for other interpixel non-linearity effects such as classical non-linearity and inter-pixel capacitance, we quantify the magnitude of the BFE by calculating the fractional area change per electron of charge contrast. We also introduce a mathematical framework to compare our results with the BFE measured on similar devices using autocorrelations from flat-field images. We find an agreement of 18 +/- 5% between the two methods. We identify potential sources of discrepancy and discuss future investigations to characterize and address them.
format Preprint
id arxiv_https___arxiv_org_abs_2310_01920
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle Spot-Based Measurement of the Brighter-Fatter Effect on a Roman Space Telescope H4RG Detector and Comparison with Flat-Field Data
Malagón, Andrés A. Plazas
Shapiro, Charles
Choi, Ami
Hirata, Chris
Instrumentation and Methods for Astrophysics
We present the measurement and characterization of the brighter-fatter effect (BFE) on a NASA Roman Space Telescope development Teledyne H4RG-10 near-infrared detector using laboratory measurements with projected point sources. After correcting for other interpixel non-linearity effects such as classical non-linearity and inter-pixel capacitance, we quantify the magnitude of the BFE by calculating the fractional area change per electron of charge contrast. We also introduce a mathematical framework to compare our results with the BFE measured on similar devices using autocorrelations from flat-field images. We find an agreement of 18 +/- 5% between the two methods. We identify potential sources of discrepancy and discuss future investigations to characterize and address them.
title Spot-Based Measurement of the Brighter-Fatter Effect on a Roman Space Telescope H4RG Detector and Comparison with Flat-Field Data
topic Instrumentation and Methods for Astrophysics
url https://arxiv.org/abs/2310.01920