Simulating the secondary electron avalanche of MCP by Geant4

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Peng, Huaxing, Yan, Baojun, Miao, Han, Liu, Shulin, Zhang, Binting
Format: Preprint
Publié: 2023
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866914815739428864
author Peng, Huaxing
Yan, Baojun
Miao, Han
Liu, Shulin
Zhang, Binting
author_facet Peng, Huaxing
Yan, Baojun
Miao, Han
Liu, Shulin
Zhang, Binting
contents Nowadays, Microchannel Plate (MCP), as a kind of electron multipliers based on the secondary electron emission, is widely used in many high-sensitive experiments, such as neutrino detection, which require the noise to be as low as possible, while the conventional straight-channel MCP will inevitably have ion feedback, resulting in the sequential after-pulses being the major source of noise. Normally, the problem can be effectively avoided by coupling two straight-channel MCPs in cascade and combining the channels into a `V` shape known as chevron MCPs, but this method is limited by the manufacturing techniques due to the unavoidable gap between the two pieces that will worsen the resolution and peak-to-valley ratio. However, the ion feedback can be inhibited significantly for MCPs with curved channels. Based on Geant4, we investigate how the geometrical parameters of curved-channel MCP influence the gain and get the optimum pore diameter for an MCP to reach the maximum gain with fixed thickness and applied voltage. Additionally, the track-by-track simulation reveals that the average acceleration distance of a secondary electron inside the curved-channel is approximately 20 um when the applied voltage, length-to-diameter ratio and pore diameter are 950 V, 50:1 and 20 um, respectively.
format Preprint
id arxiv_https___arxiv_org_abs_2310_07153
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle Simulating the secondary electron avalanche of MCP by Geant4
Peng, Huaxing
Yan, Baojun
Miao, Han
Liu, Shulin
Zhang, Binting
Instrumentation and Detectors
Nowadays, Microchannel Plate (MCP), as a kind of electron multipliers based on the secondary electron emission, is widely used in many high-sensitive experiments, such as neutrino detection, which require the noise to be as low as possible, while the conventional straight-channel MCP will inevitably have ion feedback, resulting in the sequential after-pulses being the major source of noise. Normally, the problem can be effectively avoided by coupling two straight-channel MCPs in cascade and combining the channels into a `V` shape known as chevron MCPs, but this method is limited by the manufacturing techniques due to the unavoidable gap between the two pieces that will worsen the resolution and peak-to-valley ratio. However, the ion feedback can be inhibited significantly for MCPs with curved channels. Based on Geant4, we investigate how the geometrical parameters of curved-channel MCP influence the gain and get the optimum pore diameter for an MCP to reach the maximum gain with fixed thickness and applied voltage. Additionally, the track-by-track simulation reveals that the average acceleration distance of a secondary electron inside the curved-channel is approximately 20 um when the applied voltage, length-to-diameter ratio and pore diameter are 950 V, 50:1 and 20 um, respectively.
title Simulating the secondary electron avalanche of MCP by Geant4
topic Instrumentation and Detectors
url https://arxiv.org/abs/2310.07153