Measurement of the electron-hole pair creation energy in a 4H-SiC p-n diode

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Gsponer, Andreas, Knopf, Matthias, Gaggl, Philipp, Burin, Jürgen, Waid, Simon, Bergauer, Thomas
Natura: Preprint
Pubblicazione: 2023
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866914736890707968
author Gsponer, Andreas
Knopf, Matthias
Gaggl, Philipp
Burin, Jürgen
Waid, Simon
Bergauer, Thomas
author_facet Gsponer, Andreas
Knopf, Matthias
Gaggl, Philipp
Burin, Jürgen
Waid, Simon
Bergauer, Thomas
contents For 4H silicon carbide (4H-SiC), the values for the electron-hole pair creation energy $ε_{\text{i}}$ published in the literature vary significantly. This work presents an experimental determination of $ε_{\text{i}}$ using $50$ $μ$m 4H-SiC p-n diodes designed for particle detection in high-energy physics. The detector response was measured for $α$ particles between 4.2 MeV and 5.6 MeV for 4H-SiC and a silicon reference device. Different $α$ energies were obtained by using multiple nuclides and varying the effective air gap between the $α$ source and the detector. The energy deposited in the detectors was determined using a Monte Carlo simulation, taking into account the device cross-sections. A linear fit of the detector response to the deposited energy yields $ε_{\text{i}} = (7.83 \pm 0.02)\;\text{eV}$, which agrees well with the most recent literature. For the 4H-SiC detectors, a linewidth of 28 keV FWHM was achieved, corresponding to an energy resolution of 0.5\%.
format Preprint
id arxiv_https___arxiv_org_abs_2311_03902
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle Measurement of the electron-hole pair creation energy in a 4H-SiC p-n diode
Gsponer, Andreas
Knopf, Matthias
Gaggl, Philipp
Burin, Jürgen
Waid, Simon
Bergauer, Thomas
Instrumentation and Detectors
For 4H silicon carbide (4H-SiC), the values for the electron-hole pair creation energy $ε_{\text{i}}$ published in the literature vary significantly. This work presents an experimental determination of $ε_{\text{i}}$ using $50$ $μ$m 4H-SiC p-n diodes designed for particle detection in high-energy physics. The detector response was measured for $α$ particles between 4.2 MeV and 5.6 MeV for 4H-SiC and a silicon reference device. Different $α$ energies were obtained by using multiple nuclides and varying the effective air gap between the $α$ source and the detector. The energy deposited in the detectors was determined using a Monte Carlo simulation, taking into account the device cross-sections. A linear fit of the detector response to the deposited energy yields $ε_{\text{i}} = (7.83 \pm 0.02)\;\text{eV}$, which agrees well with the most recent literature. For the 4H-SiC detectors, a linewidth of 28 keV FWHM was achieved, corresponding to an energy resolution of 0.5\%.
title Measurement of the electron-hole pair creation energy in a 4H-SiC p-n diode
topic Instrumentation and Detectors
url https://arxiv.org/abs/2311.03902