One Signal-Noise Separation based Wiener Filter for Magnetogastrogram

Fuente: arXiv
Saved in:
Bibliographic Details
Main Author: Li, Hua
Format: Preprint
Published: 2023
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866912251053604864
author Li, Hua
author_facet Li, Hua
contents Magnetogastrogram (MGG) signal frequency is about 0.05 Hz, the low-frequency environmental noise interference is serious and can be several times stronger in magnitude than the signals of interest and may severely impede the extraction of relevant information. Wiener filter is one classic denoising solution for biomagnetic applications. Since the reference channels are usually placed not far enough from the biomagnetic sources under test, they will inevitably detect the signals and the Wiener filters may produce ill-conditioned solutions. Considering the solutions to improve the signal-to-noise ratio (SNR) of Wiener filter output, there are few methods to separate the signals from the noises of the reference signal at the filter input. In this paper, a new signal processing framework called signal-noise separation based Wiener filter (SNSWF) is proposed that it separates the main noise as the input signal of the filter to improve the output SNR of Wiener filter. The filter was successfully applied to the noise suppression for MGG signal detection. Using the SNSWF, the filter SNR is 16.7 dB better than the classic Wiener filter.
format Preprint
id arxiv_https___arxiv_org_abs_2311_06739
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle One Signal-Noise Separation based Wiener Filter for Magnetogastrogram
Li, Hua
Signal Processing
Magnetogastrogram (MGG) signal frequency is about 0.05 Hz, the low-frequency environmental noise interference is serious and can be several times stronger in magnitude than the signals of interest and may severely impede the extraction of relevant information. Wiener filter is one classic denoising solution for biomagnetic applications. Since the reference channels are usually placed not far enough from the biomagnetic sources under test, they will inevitably detect the signals and the Wiener filters may produce ill-conditioned solutions. Considering the solutions to improve the signal-to-noise ratio (SNR) of Wiener filter output, there are few methods to separate the signals from the noises of the reference signal at the filter input. In this paper, a new signal processing framework called signal-noise separation based Wiener filter (SNSWF) is proposed that it separates the main noise as the input signal of the filter to improve the output SNR of Wiener filter. The filter was successfully applied to the noise suppression for MGG signal detection. Using the SNSWF, the filter SNR is 16.7 dB better than the classic Wiener filter.
title One Signal-Noise Separation based Wiener Filter for Magnetogastrogram
topic Signal Processing
url https://arxiv.org/abs/2311.06739