Measurements of time resolution of the RD50-MPW2 DMAPS prototype using TCT and $^{90}\mathrm{Sr}$

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Debevc, J., Franks, M., Hiti, B., Kraemer, U., Kramberger, G., Mandić, I., Marco-Hernández, R., Nobels, D. J. L., Powell, S., Sonneveld, J., Steininger, H., Tsolanta, C., Vilella, E., Zhang, C.
Format: Preprint
Published: 2023
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866914820085776384
author Debevc, J.
Franks, M.
Hiti, B.
Kraemer, U.
Kramberger, G.
Mandić, I.
Marco-Hernández, R.
Nobels, D. J. L.
Powell, S.
Sonneveld, J.
Steininger, H.
Tsolanta, C.
Vilella, E.
Zhang, C.
author_facet Debevc, J.
Franks, M.
Hiti, B.
Kraemer, U.
Kramberger, G.
Mandić, I.
Marco-Hernández, R.
Nobels, D. J. L.
Powell, S.
Sonneveld, J.
Steininger, H.
Tsolanta, C.
Vilella, E.
Zhang, C.
contents Results in this paper present an in-depth study of time resolution for active pixels of the RD50-MPW2 prototype CMOS particle detector. Measurement techniques employed include Backside- and Edge-TCT configurations, in addition to electrons from a $^{90}\mathrm{Sr}$ source. A sample irradiated to $5\cdot 10^{14}\,\mathrm{n}_\mathrm{eq}/\mathrm{cm}^2$ was used to study the effect of radiation damage. Timing performance was evaluated for the entire pixel matrix and with positional sensitivity within individual pixels as a function of the deposited charge. Time resolution obtained with TCT is seen to be uniform throughout the pixel's central region with approx. $220\,\mathrm{ps}$ at $12\,\mathrm{ke}^-$ of deposited charge, degrading at the edges and lower values of deposited charge. $^{90}\mathrm{Sr}$ measurements show a slightly worse time resolution as a result of delayed events coming from the peripheral areas of the pixel.
format Preprint
id arxiv_https___arxiv_org_abs_2312_01793
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle Measurements of time resolution of the RD50-MPW2 DMAPS prototype using TCT and $^{90}\mathrm{Sr}$
Debevc, J.
Franks, M.
Hiti, B.
Kraemer, U.
Kramberger, G.
Mandić, I.
Marco-Hernández, R.
Nobels, D. J. L.
Powell, S.
Sonneveld, J.
Steininger, H.
Tsolanta, C.
Vilella, E.
Zhang, C.
Instrumentation and Detectors
Results in this paper present an in-depth study of time resolution for active pixels of the RD50-MPW2 prototype CMOS particle detector. Measurement techniques employed include Backside- and Edge-TCT configurations, in addition to electrons from a $^{90}\mathrm{Sr}$ source. A sample irradiated to $5\cdot 10^{14}\,\mathrm{n}_\mathrm{eq}/\mathrm{cm}^2$ was used to study the effect of radiation damage. Timing performance was evaluated for the entire pixel matrix and with positional sensitivity within individual pixels as a function of the deposited charge. Time resolution obtained with TCT is seen to be uniform throughout the pixel's central region with approx. $220\,\mathrm{ps}$ at $12\,\mathrm{ke}^-$ of deposited charge, degrading at the edges and lower values of deposited charge. $^{90}\mathrm{Sr}$ measurements show a slightly worse time resolution as a result of delayed events coming from the peripheral areas of the pixel.
title Measurements of time resolution of the RD50-MPW2 DMAPS prototype using TCT and $^{90}\mathrm{Sr}$
topic Instrumentation and Detectors
url https://arxiv.org/abs/2312.01793