1720nm-1800nm tunable chirped pulse amplification based on thulium-doped fiber

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Liu, Xinyang, Gumenyuk, Regina
Formato: Preprint
Publicado: 2023
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866909196470976512
author Liu, Xinyang
Gumenyuk, Regina
author_facet Liu, Xinyang
Gumenyuk, Regina
contents Chirped pulse amplification (CPA) has been adopted as a commonly used methodology to obtain powerful ultrashort laser pulses since its first demonstration. However, wavelength-tunable CPA systems are rarely reported. Wavelength-tunable ultrashort and intense laser pulses are desired in various fields like nonlinear spectroscopy and optical parametric amplification. In this work, we report a 1720 nm -1800 nm tunable CPA system based on a single-mode Tm-doped fiber covering the middle wavelength band of the third biological window. The tunable CPA system delivers ultrashort pulses varied between ~300 to 500 fs depending on the central wavelength emission at the fixed repetition rate of 22.7 MHz. The maximum average power ranges from 126 mW at 1720 nm to 294 mW at 1800 nm following the gain shape of Tm-doped fiber. Considering the specific wave-length range, this tunable CPA system is highly desired for biomedical imaging, sensing and parametric amplifiers for mid-infrared light generation.
format Preprint
id arxiv_https___arxiv_org_abs_2312_06223
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle 1720nm-1800nm tunable chirped pulse amplification based on thulium-doped fiber
Liu, Xinyang
Gumenyuk, Regina
Optics
Chirped pulse amplification (CPA) has been adopted as a commonly used methodology to obtain powerful ultrashort laser pulses since its first demonstration. However, wavelength-tunable CPA systems are rarely reported. Wavelength-tunable ultrashort and intense laser pulses are desired in various fields like nonlinear spectroscopy and optical parametric amplification. In this work, we report a 1720 nm -1800 nm tunable CPA system based on a single-mode Tm-doped fiber covering the middle wavelength band of the third biological window. The tunable CPA system delivers ultrashort pulses varied between ~300 to 500 fs depending on the central wavelength emission at the fixed repetition rate of 22.7 MHz. The maximum average power ranges from 126 mW at 1720 nm to 294 mW at 1800 nm following the gain shape of Tm-doped fiber. Considering the specific wave-length range, this tunable CPA system is highly desired for biomedical imaging, sensing and parametric amplifiers for mid-infrared light generation.
title 1720nm-1800nm tunable chirped pulse amplification based on thulium-doped fiber
topic Optics
url https://arxiv.org/abs/2312.06223