Performance testing of gas-tight portable RPC for muography applications

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Kumar, V., Basnet, S., Gil, E. Cortina, Demin, P., Gamage, R. M. I. D., Giammanco, A., Karnam, R., Moussawi, M., Samalan, A., Tytgat, M., Youssef, A.
Format: Preprint
Published: 2023
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866914689492975616
author Kumar, V.
Basnet, S.
Gil, E. Cortina
Demin, P.
Gamage, R. M. I. D.
Giammanco, A.
Karnam, R.
Moussawi, M.
Samalan, A.
Tytgat, M.
Youssef, A.
author_facet Kumar, V.
Basnet, S.
Gil, E. Cortina
Demin, P.
Gamage, R. M. I. D.
Giammanco, A.
Karnam, R.
Moussawi, M.
Samalan, A.
Tytgat, M.
Youssef, A.
contents This paper reports the latest developmental efforts for a position-sensitive glass-based Resistive Plate Chamber (RPC) and a multi-channel Data AcQuisition (DAQ) system tailored for muon tracking in muography applications. The designed setup prioritizes portability, aiming for field applications where both the detector and the DAQ operate effectively in external environmental conditions. Comprehensive discussions on hardware development activities and signal processing techniques are included, incorporating noise filtering to enhance the accurate detection of real muons. A muon absorption measurement has also been carried out to understand the behavior of these detectors from an application perspective.
format Preprint
id arxiv_https___arxiv_org_abs_2312_07204
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle Performance testing of gas-tight portable RPC for muography applications
Kumar, V.
Basnet, S.
Gil, E. Cortina
Demin, P.
Gamage, R. M. I. D.
Giammanco, A.
Karnam, R.
Moussawi, M.
Samalan, A.
Tytgat, M.
Youssef, A.
Instrumentation and Detectors
High Energy Physics - Experiment
This paper reports the latest developmental efforts for a position-sensitive glass-based Resistive Plate Chamber (RPC) and a multi-channel Data AcQuisition (DAQ) system tailored for muon tracking in muography applications. The designed setup prioritizes portability, aiming for field applications where both the detector and the DAQ operate effectively in external environmental conditions. Comprehensive discussions on hardware development activities and signal processing techniques are included, incorporating noise filtering to enhance the accurate detection of real muons. A muon absorption measurement has also been carried out to understand the behavior of these detectors from an application perspective.
title Performance testing of gas-tight portable RPC for muography applications
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2312.07204