CFD analysis of the influence of contraction size on electroviscous flow through the slit-type non-uniform microfluidic device

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Dhakar, Jitendra, Bharti, Ram Prakash
Natura: Preprint
Pubblicazione: 2023
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866910498051588096
author Dhakar, Jitendra
Bharti, Ram Prakash
author_facet Dhakar, Jitendra
Bharti, Ram Prakash
contents The electroviscous effects are relevant in controlling and manipulating the fluid, thermal, and mass transport microfluidic processes. The existing research has mainly focused on the fixed contraction ratio ($d_\text{c}$, i.e., the area ratio of contraction to expansion) concerning the widely used contraction-expansion geometrical arrangement. This study has explored the influence of the contraction ratio ($d_\text{c}$) on the electroviscous flow of electrolyte liquids through the charged non-uniform microfluidic device. The numerical solution of the mathematical model (Poisson's, Nernst-Planck, and Navier-Stokes) using a finite element method (FEM) yields the local flow fields. In general, the contraction ratio significantly affects the hydrodynamic characteristics of microfluidic devices. The total electrical potential and pressure drop maximally increase by {1785\% and 2300\%}, respectively, with an overall contraction ratio ($0.25\le d_\text{c}\le 1$). Further, an electroviscous correction factor ($Y$, i.e., the ratio of apparent to physical viscosity) maximally enhances by 11.24\% (at $K=8$, $S=16$ for $0.25\le d_\text{c}\le 1$), 31.80\% (at $S=16$, $d_\text{c}=0.75$ for $2\le K\le 20$), 22.89\% (at $K=2$, $d_\text{c}=0.5$ for $4\le S\le 16$), and 46.99\% (at $K=2$, $d_\text{c}=0.75$ for $0\le S \le 16$). The present numerical results may provide valuable guidelines for the performance optimization and design of reliable and essential microfluidic devices.
format Preprint
id arxiv_https___arxiv_org_abs_2312_15928
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle CFD analysis of the influence of contraction size on electroviscous flow through the slit-type non-uniform microfluidic device
Dhakar, Jitendra
Bharti, Ram Prakash
Fluid Dynamics
The electroviscous effects are relevant in controlling and manipulating the fluid, thermal, and mass transport microfluidic processes. The existing research has mainly focused on the fixed contraction ratio ($d_\text{c}$, i.e., the area ratio of contraction to expansion) concerning the widely used contraction-expansion geometrical arrangement. This study has explored the influence of the contraction ratio ($d_\text{c}$) on the electroviscous flow of electrolyte liquids through the charged non-uniform microfluidic device. The numerical solution of the mathematical model (Poisson's, Nernst-Planck, and Navier-Stokes) using a finite element method (FEM) yields the local flow fields. In general, the contraction ratio significantly affects the hydrodynamic characteristics of microfluidic devices. The total electrical potential and pressure drop maximally increase by {1785\% and 2300\%}, respectively, with an overall contraction ratio ($0.25\le d_\text{c}\le 1$). Further, an electroviscous correction factor ($Y$, i.e., the ratio of apparent to physical viscosity) maximally enhances by 11.24\% (at $K=8$, $S=16$ for $0.25\le d_\text{c}\le 1$), 31.80\% (at $S=16$, $d_\text{c}=0.75$ for $2\le K\le 20$), 22.89\% (at $K=2$, $d_\text{c}=0.5$ for $4\le S\le 16$), and 46.99\% (at $K=2$, $d_\text{c}=0.75$ for $0\le S \le 16$). The present numerical results may provide valuable guidelines for the performance optimization and design of reliable and essential microfluidic devices.
title CFD analysis of the influence of contraction size on electroviscous flow through the slit-type non-uniform microfluidic device
topic Fluid Dynamics
url https://arxiv.org/abs/2312.15928