CFD analysis of electroviscous effects in electrolyte liquid flow through heterogeneously charged uniform microfluidic device

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Dhakar, Jitendra, Bharti, Ram Prakash
Format: Preprint
Published: 2023
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866917785946292224
author Dhakar, Jitendra
Bharti, Ram Prakash
author_facet Dhakar, Jitendra
Bharti, Ram Prakash
contents This study has numerically investigated the charge-heterogeneity effects in the electroviscous flow of symmetric ($1$:$1$) electrolyte liquid through a uniform slit microfluidic device. The Poisson's, Nernst-Planck (N-P), Navier-Stokes (N-S), and continuity equations are solved using the finite element method (FEM) to obtain the flow fields, such as total electrical potential ($U$), excess charge ($n^\ast$), induced electric field strength ($E_\text{x}$), and pressure ($P$) fields for following conditions: inverse Debye length ($2\le K\le 20$), surface charge density ($4\le \mathit{S_\text{1}}\le 16$), and surface charge-heterogeneity ratio ($0\le \mathit{S_\text{rh}}\le 2$). Results have shown that the total potential ($|ΔU|$) and pressure ($|ΔP|$) drop maximally increase by 99.09% (at $K=20$, $\mathit{S_\text{1}}=4$) and 12.77% (at $K=2$, $\mathit{S_\text{1}}=8$), respectively with overall charge-heterogeneity ($0\le \mathit{S_\text{rh}}\le 2$). Electroviscous correction factor (i.e., the ratio of effective to physical viscosity) maximally enhances by 12.77% (at $K=2$, $\mathit{S_\text{1}}=8$), 40.98% (at $\mathit{S_\text{1}}=16$, $\mathit{S_\text{rh}}=1.50$), and 41.35% (at $K=2$, $\mathit{S_\text{rh}}=1.50$), with the variation of $\mathit{S_\text{rh}}$ (from 0 to 2), $K$ (from 20 to 2), and $\mathit{S_\text{1}}$ (from 0 to 16), respectively. Further, a simple pseudo-analytical model is developed to estimate the pressure drop in the electroviscous (EV) flow, accounting for the influence of charge-heterogeneity based on the Poiseuille flow in the uniform channel. This model predicts the pressure drop $\pm$2-4% within the numerical results. The robustness and simplicity of this model enable the present numerical results for engineering and design aspects of microfluidic applications.
format Preprint
id arxiv_https___arxiv_org_abs_2312_16032
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle CFD analysis of electroviscous effects in electrolyte liquid flow through heterogeneously charged uniform microfluidic device
Dhakar, Jitendra
Bharti, Ram Prakash
Fluid Dynamics
This study has numerically investigated the charge-heterogeneity effects in the electroviscous flow of symmetric ($1$:$1$) electrolyte liquid through a uniform slit microfluidic device. The Poisson's, Nernst-Planck (N-P), Navier-Stokes (N-S), and continuity equations are solved using the finite element method (FEM) to obtain the flow fields, such as total electrical potential ($U$), excess charge ($n^\ast$), induced electric field strength ($E_\text{x}$), and pressure ($P$) fields for following conditions: inverse Debye length ($2\le K\le 20$), surface charge density ($4\le \mathit{S_\text{1}}\le 16$), and surface charge-heterogeneity ratio ($0\le \mathit{S_\text{rh}}\le 2$). Results have shown that the total potential ($|ΔU|$) and pressure ($|ΔP|$) drop maximally increase by 99.09% (at $K=20$, $\mathit{S_\text{1}}=4$) and 12.77% (at $K=2$, $\mathit{S_\text{1}}=8$), respectively with overall charge-heterogeneity ($0\le \mathit{S_\text{rh}}\le 2$). Electroviscous correction factor (i.e., the ratio of effective to physical viscosity) maximally enhances by 12.77% (at $K=2$, $\mathit{S_\text{1}}=8$), 40.98% (at $\mathit{S_\text{1}}=16$, $\mathit{S_\text{rh}}=1.50$), and 41.35% (at $K=2$, $\mathit{S_\text{rh}}=1.50$), with the variation of $\mathit{S_\text{rh}}$ (from 0 to 2), $K$ (from 20 to 2), and $\mathit{S_\text{1}}$ (from 0 to 16), respectively. Further, a simple pseudo-analytical model is developed to estimate the pressure drop in the electroviscous (EV) flow, accounting for the influence of charge-heterogeneity based on the Poiseuille flow in the uniform channel. This model predicts the pressure drop $\pm$2-4% within the numerical results. The robustness and simplicity of this model enable the present numerical results for engineering and design aspects of microfluidic applications.
title CFD analysis of electroviscous effects in electrolyte liquid flow through heterogeneously charged uniform microfluidic device
topic Fluid Dynamics
url https://arxiv.org/abs/2312.16032