Variability of morphology in beat-to-beat photoplethysmographic waveform quantified with unsupervised wave-shape manifold learning for clinical assessment

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Ho, Yu-Chieh, Lin, Te-Sheng, Wang, She-Chih, Chang, Chen-Shi, Lin, Yu-Ting
Format: Preprint
Published: 2023
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866912283195604992
author Ho, Yu-Chieh
Lin, Te-Sheng
Wang, She-Chih
Chang, Chen-Shi
Lin, Yu-Ting
author_facet Ho, Yu-Chieh
Lin, Te-Sheng
Wang, She-Chih
Chang, Chen-Shi
Lin, Yu-Ting
contents We investigated the beat-to-beat fluctuation of the photoplethysmography (PPG) waveform. The motivation is that morphology variability extracted from the arterial blood pressure (ABP) has been found to correlate with baseline condition and short-term surgical outcome of the patients undergoing liver transplant surgery. Numerous interactions of physiological mechanisms regulating the cardiovascular system could underlie the variability of morphology. We used the unsupervised manifold learning algorithm, Dynamic Diffusion Map, to quantify the multivariate waveform morphological variation. Due to the physical principle of light absorption, PPG waveform signals are more susceptible to artifact and are nominally used only for visual inspection of data quality in clinical medical environment. But on the other hand, the noninvasive, easy-to-use nature of PPG grants a wider range of biomedical application, which inspired us to investigate the variability of morphology information from PPG waveform signal. We developed data analysis techniques to improve the performance and validated with the real-life clinical database.
format Preprint
id arxiv_https___arxiv_org_abs_2401_00173
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle Variability of morphology in beat-to-beat photoplethysmographic waveform quantified with unsupervised wave-shape manifold learning for clinical assessment
Ho, Yu-Chieh
Lin, Te-Sheng
Wang, She-Chih
Chang, Chen-Shi
Lin, Yu-Ting
Quantitative Methods
We investigated the beat-to-beat fluctuation of the photoplethysmography (PPG) waveform. The motivation is that morphology variability extracted from the arterial blood pressure (ABP) has been found to correlate with baseline condition and short-term surgical outcome of the patients undergoing liver transplant surgery. Numerous interactions of physiological mechanisms regulating the cardiovascular system could underlie the variability of morphology. We used the unsupervised manifold learning algorithm, Dynamic Diffusion Map, to quantify the multivariate waveform morphological variation. Due to the physical principle of light absorption, PPG waveform signals are more susceptible to artifact and are nominally used only for visual inspection of data quality in clinical medical environment. But on the other hand, the noninvasive, easy-to-use nature of PPG grants a wider range of biomedical application, which inspired us to investigate the variability of morphology information from PPG waveform signal. We developed data analysis techniques to improve the performance and validated with the real-life clinical database.
title Variability of morphology in beat-to-beat photoplethysmographic waveform quantified with unsupervised wave-shape manifold learning for clinical assessment
topic Quantitative Methods
url https://arxiv.org/abs/2401.00173