contents With the expanding reach of physics, xenon-based detectors such as PandaX-4T in the China Jinping Underground Laboratory aim to cover an energy range from sub-keV to multi-MeV. A linear response of the photomultiplier tubes (PMTs) is required for both scintillation and electroluminescence signals. Through a dedicated bench test, we investigated the cause of the non-linear response in the Hamamatsu R11410-23 PMTs used in PandaX-4T. The saturation and suppression of the PMT waveform observed during the commissioning of PandaX-4T were caused by the high-voltage divider base. The bench test data validated the de-saturation algorithm used in the PandaX-4T data analysis. We also confirmed the improvement in linearity of a new PMT base design, which will be used to upgrade the PMT readout system in PandaX-4T.
format Preprint
id arxiv_https___arxiv_org_abs_2401_00373
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle Improvement on the Linearity Response of PandaX-4T with new Photomultiplier Tubes Bases
Luo, Lingyin
Fang, Deqing
Han, Ke
Huang, Di
Shang, Xiaofeng
Wang, Anqing
Wang, Qiuhong
Wang, Shaobo
Wang, Siguang
Xiao, Xiang
Yan, Binbin
Yan, Xiyu
Instrumentation and Detectors
High Energy Physics - Experiment
With the expanding reach of physics, xenon-based detectors such as PandaX-4T in the China Jinping Underground Laboratory aim to cover an energy range from sub-keV to multi-MeV. A linear response of the photomultiplier tubes (PMTs) is required for both scintillation and electroluminescence signals. Through a dedicated bench test, we investigated the cause of the non-linear response in the Hamamatsu R11410-23 PMTs used in PandaX-4T. The saturation and suppression of the PMT waveform observed during the commissioning of PandaX-4T were caused by the high-voltage divider base. The bench test data validated the de-saturation algorithm used in the PandaX-4T data analysis. We also confirmed the improvement in linearity of a new PMT base design, which will be used to upgrade the PMT readout system in PandaX-4T.
title Improvement on the Linearity Response of PandaX-4T with new Photomultiplier Tubes Bases