Radon Removal Commissioning of the PandaX-4T Cryogenic Distillation System

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Cui, Xiangyi, Wang, Zhou, Li, Jiafu, Li, Shuaijie, Si, Lin, Ju, Yonglin, Ma, Wenbo, Liu, Jianglai, Zhao, Li, Ji, Xiangdong, Yan, Rui, Sha, Haidong, Huang, Peiyao, Wang, Xiuli, Liu, Huaxuan
Format: Preprint
Publié: 2024
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866913321842638848
author Cui, Xiangyi
Wang, Zhou
Li, Jiafu
Li, Shuaijie
Si, Lin
Ju, Yonglin
Ma, Wenbo
Liu, Jianglai
Zhao, Li
Ji, Xiangdong
Yan, Rui
Sha, Haidong
Huang, Peiyao
Wang, Xiuli
Liu, Huaxuan
author_facet Cui, Xiangyi
Wang, Zhou
Li, Jiafu
Li, Shuaijie
Si, Lin
Ju, Yonglin
Ma, Wenbo
Liu, Jianglai
Zhao, Li
Ji, Xiangdong
Yan, Rui
Sha, Haidong
Huang, Peiyao
Wang, Xiuli
Liu, Huaxuan
contents The PandaX-4T distillation system, designed for the removal of krypton and radon from xenon, is evaluated for its radon removal efficiency using a $^{222}$Rn source during the online distillation process. The PandaX-4T dark matter detector is employed to monitor the temporal evolution of radon activity. To determine the radon reduction factor, the experimental data of radon atoms introduced into and bypassed the distillation system is compared. The results indicate that the PandaX-4T distillation system achieves a radon reduction factor exceeding 190 at the flow rate of 10 slpm and the reflux ratio of 1.44. Gas-only online distillation process of a flow rate of 20 slpm is also conducted without observing significant reduction of radon levels in the detector. This observation suggests that the migration flow of radon atoms from the liquid phase to the gas phase is limited, and the flow rate of gas circulation and duration of the process are insignificant compared to the total xenon mass of 5.6 tons in the detector. This study provides the experimental data to support the efficient removal of radon at $\sim$Bq level using the PandaX-4T distillation system, which is the prerequisite of the radon background control in the detector. The further operation with higher flow rate will be applied for the upcoming science run in PandaX-4T.
format Preprint
id arxiv_https___arxiv_org_abs_2401_01638
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Radon Removal Commissioning of the PandaX-4T Cryogenic Distillation System
Cui, Xiangyi
Wang, Zhou
Li, Jiafu
Li, Shuaijie
Si, Lin
Ju, Yonglin
Ma, Wenbo
Liu, Jianglai
Zhao, Li
Ji, Xiangdong
Yan, Rui
Sha, Haidong
Huang, Peiyao
Wang, Xiuli
Liu, Huaxuan
Instrumentation and Detectors
The PandaX-4T distillation system, designed for the removal of krypton and radon from xenon, is evaluated for its radon removal efficiency using a $^{222}$Rn source during the online distillation process. The PandaX-4T dark matter detector is employed to monitor the temporal evolution of radon activity. To determine the radon reduction factor, the experimental data of radon atoms introduced into and bypassed the distillation system is compared. The results indicate that the PandaX-4T distillation system achieves a radon reduction factor exceeding 190 at the flow rate of 10 slpm and the reflux ratio of 1.44. Gas-only online distillation process of a flow rate of 20 slpm is also conducted without observing significant reduction of radon levels in the detector. This observation suggests that the migration flow of radon atoms from the liquid phase to the gas phase is limited, and the flow rate of gas circulation and duration of the process are insignificant compared to the total xenon mass of 5.6 tons in the detector. This study provides the experimental data to support the efficient removal of radon at $\sim$Bq level using the PandaX-4T distillation system, which is the prerequisite of the radon background control in the detector. The further operation with higher flow rate will be applied for the upcoming science run in PandaX-4T.
title Radon Removal Commissioning of the PandaX-4T Cryogenic Distillation System
topic Instrumentation and Detectors
url https://arxiv.org/abs/2401.01638