contents By means of numerical simulations, we demonstrate the innovative use of computational ghost imaging in transmission electron microscopy to retrieve images with a resolution that overcomes the limitations imposed by coherent aberrations. The method requires measuring the intensity on a single pixel detector with a series of structured illuminations. The success of the technique is improved if the probes are made to resemble the sample and the patterns cover the area of interest evenly. By using a simple 8 electrode device as a specific example, a 2-fold increase in resolution beyond the aberration limit is demonstrated to be possible under realistic experimental conditions.
format Preprint
id arxiv_https___arxiv_org_abs_2401_01898
institution arXiv
publishDate 2023
record_format arxiv
spellingShingle Increasing the resolution of transmission electron microscopy by computational ghost imaging
Rosi, P.
Viani, L.
Rotunno, E.
Frabboni, S.
Tavabi, A. H.
Dunin-Borkowski, R. E.
Roncaglia, A.
Grillo, V.
Instrumentation and Detectors
Optics
By means of numerical simulations, we demonstrate the innovative use of computational ghost imaging in transmission electron microscopy to retrieve images with a resolution that overcomes the limitations imposed by coherent aberrations. The method requires measuring the intensity on a single pixel detector with a series of structured illuminations. The success of the technique is improved if the probes are made to resemble the sample and the patterns cover the area of interest evenly. By using a simple 8 electrode device as a specific example, a 2-fold increase in resolution beyond the aberration limit is demonstrated to be possible under realistic experimental conditions.