Guardado en:
| Autores principales: | , , |
|---|---|
| Formato: | Preprint |
| Publicado: |
2024
|
| Materias: | |
| Acceso en línea: | https://arxiv.org/abs/2401.02127 |
| Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
| _version_ | 1866910287157788672 |
|---|---|
| author | Choi, Jeakyung Hwang, Hyeok Kim, Eunseong |
| author_facet | Choi, Jeakyung Hwang, Hyeok Kim, Eunseong |
| contents | High power measurement-induced cavity response is investigated in the |g>, |e>, and |f> states of a transmon. All the states exhibit photon blockades above a certain critical value, a phenomenon that has previously been understood based on the bistability of semiclassical Duffing oscillators. The measurement-induced state transition (MIST) to high-level transmon states is expected to be one contributor to the bistability; however, the critical values measured in the |e> and |f> states are not coincident with the MIST. To understand this discrepancy, we utilize the recently developed semiclassical dynamics model of a cavity photon state. The appearance of dim and bright cavity states obtained from the model's steady-state solution leads to the photon blockades at lower critical photon numbers, and this can explain the response of the bistable region in the |e> and |f> states. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2401_02127 |
| institution | arXiv |
| publishDate | 2024 |
| record_format | arxiv |
| spellingShingle | Measurement-induced bistability in the excited states of a transmon Choi, Jeakyung Hwang, Hyeok Kim, Eunseong Quantum Physics High power measurement-induced cavity response is investigated in the |g>, |e>, and |f> states of a transmon. All the states exhibit photon blockades above a certain critical value, a phenomenon that has previously been understood based on the bistability of semiclassical Duffing oscillators. The measurement-induced state transition (MIST) to high-level transmon states is expected to be one contributor to the bistability; however, the critical values measured in the |e> and |f> states are not coincident with the MIST. To understand this discrepancy, we utilize the recently developed semiclassical dynamics model of a cavity photon state. The appearance of dim and bright cavity states obtained from the model's steady-state solution leads to the photon blockades at lower critical photon numbers, and this can explain the response of the bistable region in the |e> and |f> states. |
| title | Measurement-induced bistability in the excited states of a transmon |
| topic | Quantum Physics |
| url | https://arxiv.org/abs/2401.02127 |