A coronary artery phantom for task-based CT performance assessment and a comparative study of clinical CT, photon counting CT, and micro CT

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Pack, Jed D., Fitzgerald, Paul, Araujo, Stephen, Fan, Ying, Stevens, Grant, Gerdes, Jonathan, Wang, Adam, Nieman, Koen, Wang, Ge, De Man, Bruno
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866929203762429952
author Pack, Jed D.
Fitzgerald, Paul
Araujo, Stephen
Fan, Ying
Stevens, Grant
Gerdes, Jonathan
Wang, Adam
Nieman, Koen
Wang, Ge
De Man, Bruno
author_facet Pack, Jed D.
Fitzgerald, Paul
Araujo, Stephen
Fan, Ying
Stevens, Grant
Gerdes, Jonathan
Wang, Adam
Nieman, Koen
Wang, Ge
De Man, Bruno
contents While drastic improvements in CT technology have occurred in the past 25 years, spatial resolution is one area where progress has been limited until recently. New photon counting CT systems, are capable of much better spatial resolution than their (energy integrating) predecessors. These improvements have the potential to improve the evaluation obstructive coronary artery disease by enabling more accurate delineation between calcified plaque and coronary vessel lumen. A new set of vessel phantoms has been designed and manufactured for quantifying this improvement. Comparisons are made between an existing clinical CT system, a prototype photon counting system, with images from a micro CT system being used as the gold standard. Scans were made of the same objects on all three systems. The resulting images were registered and the luminal cross section areas were compared. Luminal cross-sections near calcified plaques were reduced due to blooming, but this effect was much less pronounced in images from the prototype photon counting system as compared to the images from the clinical CT system.
format Preprint
id arxiv_https___arxiv_org_abs_2401_04215
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle A coronary artery phantom for task-based CT performance assessment and a comparative study of clinical CT, photon counting CT, and micro CT
Pack, Jed D.
Fitzgerald, Paul
Araujo, Stephen
Fan, Ying
Stevens, Grant
Gerdes, Jonathan
Wang, Adam
Nieman, Koen
Wang, Ge
De Man, Bruno
Medical Physics
While drastic improvements in CT technology have occurred in the past 25 years, spatial resolution is one area where progress has been limited until recently. New photon counting CT systems, are capable of much better spatial resolution than their (energy integrating) predecessors. These improvements have the potential to improve the evaluation obstructive coronary artery disease by enabling more accurate delineation between calcified plaque and coronary vessel lumen. A new set of vessel phantoms has been designed and manufactured for quantifying this improvement. Comparisons are made between an existing clinical CT system, a prototype photon counting system, with images from a micro CT system being used as the gold standard. Scans were made of the same objects on all three systems. The resulting images were registered and the luminal cross section areas were compared. Luminal cross-sections near calcified plaques were reduced due to blooming, but this effect was much less pronounced in images from the prototype photon counting system as compared to the images from the clinical CT system.
title A coronary artery phantom for task-based CT performance assessment and a comparative study of clinical CT, photon counting CT, and micro CT
topic Medical Physics
url https://arxiv.org/abs/2401.04215