Lowering the Energy Threshold using a Plastic Scintillator and Radiation-Damaged SiPMs

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Morishita, Teruaki, Fukazawa, Yasushi, Takahashi, Hiromitsu, Kayanoki, Taishu, Niwa, Ryota, Hashizume, Masaki
Formato: Preprint
Publicado: 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866917575173079040
author Morishita, Teruaki
Fukazawa, Yasushi
Takahashi, Hiromitsu
Kayanoki, Taishu
Niwa, Ryota
Hashizume, Masaki
author_facet Morishita, Teruaki
Fukazawa, Yasushi
Takahashi, Hiromitsu
Kayanoki, Taishu
Niwa, Ryota
Hashizume, Masaki
contents The radiation damage to a silicon photomultiplier (SiPM) set on a satellite orbit increases energy threshold for scintillator detectors. We confirmed that 1 krad of radiation increases the energy threshold by approximately a factor of 10, which is worst for our system. Using one or two SiPMs damaged by proton irradiation and a plastic scintillator, we performed the following three experiments in our attempt to lower the energy threshold of radiation-damaged SiPMs to the greatest extent: (1) measurements using a current waveform amplifier rather than a charge-sensitive amplifier, (2) coincidence measurements with two radiation-damaged SiPMs attached to one scintillator and summing up their signals, and (3) measurements at a low temperature. Our findings confirmed that the use of a current waveform amplifier, as opposed to a charge-sensitive amplifier and a shaping amplifier, could lower the energy threshold to approximately 65% (from 198 keV to 128 keV). Furthermore, if we set the coincidence width appropriately and sum up the signals of the two SiPMs in the coincidence measurement, the energy threshold could be lowered to approximately 70% (from 132 keV to 93 keV) with little loss of the acquired signal, compared to that of use of only one scintillator. Finally, if we perform our measurements at a temperature of -20 °C, we could lower the energy threshold to approximately 34% (from 128 keV to 43 keV) compared to that of at 20 °C. Accordingly, we conclude that the energy threshold can be lowered to approximately 15% by using a combination of these three methods.
format Preprint
id arxiv_https___arxiv_org_abs_2401_05087
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Lowering the Energy Threshold using a Plastic Scintillator and Radiation-Damaged SiPMs
Morishita, Teruaki
Fukazawa, Yasushi
Takahashi, Hiromitsu
Kayanoki, Taishu
Niwa, Ryota
Hashizume, Masaki
Instrumentation and Detectors
Instrumentation and Methods for Astrophysics
The radiation damage to a silicon photomultiplier (SiPM) set on a satellite orbit increases energy threshold for scintillator detectors. We confirmed that 1 krad of radiation increases the energy threshold by approximately a factor of 10, which is worst for our system. Using one or two SiPMs damaged by proton irradiation and a plastic scintillator, we performed the following three experiments in our attempt to lower the energy threshold of radiation-damaged SiPMs to the greatest extent: (1) measurements using a current waveform amplifier rather than a charge-sensitive amplifier, (2) coincidence measurements with two radiation-damaged SiPMs attached to one scintillator and summing up their signals, and (3) measurements at a low temperature. Our findings confirmed that the use of a current waveform amplifier, as opposed to a charge-sensitive amplifier and a shaping amplifier, could lower the energy threshold to approximately 65% (from 198 keV to 128 keV). Furthermore, if we set the coincidence width appropriately and sum up the signals of the two SiPMs in the coincidence measurement, the energy threshold could be lowered to approximately 70% (from 132 keV to 93 keV) with little loss of the acquired signal, compared to that of use of only one scintillator. Finally, if we perform our measurements at a temperature of -20 °C, we could lower the energy threshold to approximately 34% (from 128 keV to 43 keV) compared to that of at 20 °C. Accordingly, we conclude that the energy threshold can be lowered to approximately 15% by using a combination of these three methods.
title Lowering the Energy Threshold using a Plastic Scintillator and Radiation-Damaged SiPMs
topic Instrumentation and Detectors
Instrumentation and Methods for Astrophysics
url https://arxiv.org/abs/2401.05087