Divergent Clinical Equivalence Findings from DVH and NTCP Metrics for Alternative OAR Delineations with Increasing Setup Variability in Head-and-Neck Radiotherapy

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Rashad, M. N. H., Karki, Abishek, Czak, Jason, Alves, Victor Gabriel, Nourzadeh, Hamidreza, Choi, Wookjin, Siebers, Jeffrey V
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866914910574739456
author Rashad, M. N. H.
Karki, Abishek
Czak, Jason
Alves, Victor Gabriel
Nourzadeh, Hamidreza
Choi, Wookjin
Siebers, Jeffrey V
author_facet Rashad, M. N. H.
Karki, Abishek
Czak, Jason
Alves, Victor Gabriel
Nourzadeh, Hamidreza
Choi, Wookjin
Siebers, Jeffrey V
contents Purpose: This study quantifies the variation in dose-volume histogram (DVH) and normal tissue complication probability (NTCP) metrics for head-and-neck (HN) cancer patients when alternative organ-at-risk (OAR) delineations are used for treatment planning and for treatment plan evaluation. We particularly focus on the effects of daily patient positioning/setup variations (SV) in relation to treatment technique and delineation variability. Materials and Methods: We generated two-arc VMAT, 5-beam IMRT, and 9-beam IMRT treatment plans for a cohort of 209 HN patients. These plans incorporated five different OAR delineation sets, including manual and four automated algorithms. Each treatment plan was assessed under various simulated per-fraction patient setup uncertainties, evaluating the potential clinical impacts through DVH and NTCP metrics. Results: The study demonstrates that increasing setup variability generally reduces differences in DVH metrics between alternative delineations. However, in contrast, differences in NTCP metrics tend to increase with higher setup variability. This pattern is observed consistently across different treatment plans and delineator combinations, illustrating the intricate relationship between SV and delineation accuracy. Additionally, the need for delineation accuracy in treatment planning is shown to be case-specific and dependent on factors beyond geometric variations. Conclusions: The findings highlight the necessity for comprehensive quality assurance programs in radiotherapy, incorporating both dosimetric impact analysis and geometric variation assessment to ensure optimal delineation quality. The study emphasizes the complex dynamics of treatment planning in radiotherapy, advocating for personalized, case-specific strategies in clinical practice to enhance patient care quality and efficacy in the face of varying SV and delineation accuracies.
format Preprint
id arxiv_https___arxiv_org_abs_2401_05656
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Divergent Clinical Equivalence Findings from DVH and NTCP Metrics for Alternative OAR Delineations with Increasing Setup Variability in Head-and-Neck Radiotherapy
Rashad, M. N. H.
Karki, Abishek
Czak, Jason
Alves, Victor Gabriel
Nourzadeh, Hamidreza
Choi, Wookjin
Siebers, Jeffrey V
Medical Physics
Purpose: This study quantifies the variation in dose-volume histogram (DVH) and normal tissue complication probability (NTCP) metrics for head-and-neck (HN) cancer patients when alternative organ-at-risk (OAR) delineations are used for treatment planning and for treatment plan evaluation. We particularly focus on the effects of daily patient positioning/setup variations (SV) in relation to treatment technique and delineation variability. Materials and Methods: We generated two-arc VMAT, 5-beam IMRT, and 9-beam IMRT treatment plans for a cohort of 209 HN patients. These plans incorporated five different OAR delineation sets, including manual and four automated algorithms. Each treatment plan was assessed under various simulated per-fraction patient setup uncertainties, evaluating the potential clinical impacts through DVH and NTCP metrics. Results: The study demonstrates that increasing setup variability generally reduces differences in DVH metrics between alternative delineations. However, in contrast, differences in NTCP metrics tend to increase with higher setup variability. This pattern is observed consistently across different treatment plans and delineator combinations, illustrating the intricate relationship between SV and delineation accuracy. Additionally, the need for delineation accuracy in treatment planning is shown to be case-specific and dependent on factors beyond geometric variations. Conclusions: The findings highlight the necessity for comprehensive quality assurance programs in radiotherapy, incorporating both dosimetric impact analysis and geometric variation assessment to ensure optimal delineation quality. The study emphasizes the complex dynamics of treatment planning in radiotherapy, advocating for personalized, case-specific strategies in clinical practice to enhance patient care quality and efficacy in the face of varying SV and delineation accuracies.
title Divergent Clinical Equivalence Findings from DVH and NTCP Metrics for Alternative OAR Delineations with Increasing Setup Variability in Head-and-Neck Radiotherapy
topic Medical Physics
url https://arxiv.org/abs/2401.05656